ADG FEA Solver 3Duser guide Back to the solver Back to ADG

FEA Solver 3D – user guide

Linear elastic static analysis of space frames: six degrees of freedom per node, twelve per member (axial, torsion, bending in two planes and shear in two directions). Everything runs in the browser; the model is kept in localStorage and can be saved as JSON.

1 · What it does

2 · Building a model

  1. Node mode (N or + Node in the left panel): click on the working plane (Z = 0 by default) to add nodes — each click snaps to 5 cm. Coordinates can be edited in the Properties panel or in the Nodes table.
  2. Member mode (M or + Member): click the first node, then the second; the member takes the first section in the list (change it in Properties).
  3. Set supports (see §4), then loads (§6), then press Solve.
  4. Demo loads a single-storey space frame (6 × 6 m, height 4 m) with gravity and wind.

The view is an orthographic projection: right-drag to orbit, middle-drag to pan, the wheel to zoom. Presets: Iso, Front (XZ), Top (XY), Side (YZ), Fit. Keyboard: 1–4 presets, F fit, N/M modes, Ctrl+Enter solve, Esc cancel, Delete remove the selection.

3 · Local axes and signs

Each member gets its own right-handed triad, independent of the viewing direction:

The Roll angle rotates y and z about the member axis (for an I-section, 90° puts the strong axis in the other plane). For a horizontal beam along X this gives y = up and z = −Y, so vertical loads bend about the strong axis (Iz) — the same convention as FEA Solver 2D.

4 · Degrees of freedom and supports

DOFMeaningTypical support
UX, UY, UZtranslationspinned base: all three
RXrotation about X (torsion for members along X)fixed base
RY, RZrotations about Y and Z (bending planes)fixed base

A node without any support is free; a pinned base in a space frame is normally UX + UY + UZ (no rotations), a fixed base adds RX + RY + RZ. The solver reports a mechanism when a translation has no stiffness anywhere, and silently restrains rotation DOFs that belong to released member ends only.

5 · Member releases

Up to six end releases per member: Ry/Rz release the bending rotation in the local x-z / x-y plane, Rx releases torsion. They are treated by static condensation, so the released end moment is exactly zero while the other members keep their full stiffness at the shared node. A configuration that makes the condensed matrix singular (for example both ends released in the same bending plane on a member carrying no other stiffness) is reported as an error instead of a silent NaN.

6 · Loads

Combinations multiply each case: e.g. 1.35·G + 1.5·Q. Select All load cases to add every case with factor 1 (useful for a quick check).

7 · Sections and the torsion constant

A section is defined by A, Iy, Iz, J (and optionally Wy, Wz, WT and the mass per metre). J is required: the torsion stiffness is GJ/L.

The Standard profile picker loads the published values from data/sections.json — 1367 profiles (CHS, SHS, RHS, L, UPN, UPE, IPE, HEA, HEB, HEM, UB, UC, UBP) with the real torsion constant IT taken from the same tables that are published on adgdesign.ro (EN 10365, EN 10210, EN 10219, EN 10056, BS 4-1). No estimate is used; if a profile had no tabulated J the tool would say so instead of guessing.

Parametric sections created inside the tool compute J from geometry: circle J = 2I, closed rectangular tube J = 2·t·(b−t)²·(h−t)² / [(b−t)+(h−t)], solid rectangle by the Roark formula.

8 · Cables and ties (tension only)

A cable is a special member that carries axial tension only: it has no bending or torsional stiffness and it goes slack instead of taking compression. Use it for guy ropes, stays, tie rods and X-bracing made of cables — anything that cannot push.

1 · Define the section. Select a section and set Type = Cable / tie (or press + Cable in the left panel). A cable section needs only the area A; Iy, Iz, J are not used and are kept at zero. Two ways to get A:

2 · Mark the members. In the member properties set Member type = Cable. Assigning a cable section to a member switches it to Cable automatically. End releases are not used on cables (they are cleared) and the mass for modal analysis is still taken from the section (ρ·A) plus any added mass.

3 · Pretension (initial force). In the member properties set Pretension [kN] — the tensile force locked into the cable before any load is applied (the cable is modelled as being shorter by ε₀ = N₀/(E·A)). The analysis reports N = N₀ + EA/L·δ, so a pretensioned cable stays active until the compression exceeds N₀; below that it goes slack and the pretension is lost, exactly like a real guy. The panel also shows the equivalent strain ε₀ and N₀ as a percentage of the breaking load Fub = A·fub. Typical initial tensions for guy ropes are 10–25 % of Fub (enough to keep the leeward guys taut under service wind); the cable section panel prints that range for the section you selected.

Cable steels. The material library has four cable steels plus a tie-rod steel, all with the breaking strength fub and the effective rope modulus (not the wire modulus):

MaterialE [GPa]fub [N/mm²]
Cable steel 1770 — rope 6×191051770
Cable steel 1770 — rope 6×371201770
Cable steel 1570 — locked coil1601570
Cable steel 1960 — strand1751960
Tie rod S355210490 (fu)

The effective modulus matters: a 6×19 rope is roughly half as stiff as solid steel in the same area, so using E = 210 GPa for a rope underestimates its elongation by ~2×. The breaking load is Fub = Ametal · fub; with a safety factor (e.g. 2.0–2.5 for guy ropes) you get the allowable tension. The tool does not apply partial factors — read N here and do the check with the ADG steel/rope data.

4 · Solve. The analysis is iterative: the structure is solved with all cables active, every cable found in compression is switched off, cables that would stretch again are switched back on, and the cycle repeats until the state no longer changes (typically 2–3 iterations). The status line reports Cables: 3/4 active (slack: M5), 2 tension-only iteration(s), and the Forces table shows cable or cable · slack in the Type column (a slack cable has N = 0 and no shear or moment; its row is not drawn with a diagram).

BehaviourWhat the solver does
Tension (N > 0)stiffness EA/L in the local x direction, force reported as N
Compression (N < 0)the cable is removed from the stiffness matrix and re-solved (slack, N = 0)
Loads on a cableapplied to the two end nodes (a bar has no bending); self weight acts as ρ·A·g on the ends
Rotations at a cable enduncoupled: a node held only by cables has no rotational stiffness (the solver labels it a gauge DOF)
All cables slackif the remaining structure is a mechanism the solver says so and mentions the slack cables — check the bracing direction

This is a first-order tension-only model: the cable is straight between its nodes, so cable sag, pretension and large-displacement (catenary) behaviour are not included. For a guyed mast this is the usual hand-calculation model and it gives the governing forces; if as built pretension matters, design the guys with the rope supplier's data and check the mast for the loss of one guy.

Stability tip. Radial guys do not restrain rotation about the mast axis, so a mast whose base is only pinned (translations fixed, rotations free) is a torsional mechanism and the solver reports a singular matrix at the top node (RZ). Support RZ at the base (a foundation block) or leave the base fixed — that is how a guyed mast is normally built. The same applies to a node held only by cables: it has no rotational stiffness.

9 · Reading the results

QuantityConvention
Naxial force, tension positive
Vy, Vzshear forces along the local y / z axes
Mxtorsional moment about the local x axis, right-hand rule
Mzbending in the local x-y plane (strong axis for a horizontal beam)
Mybending in the local x-z plane

Diagrams are drawn in the member's local plane and scaled by Diagram scale; the maximum value is printed on each member. The Deformed view is scaled automatically (8 % of the model span). All tables use the units chosen in the Units panel.

After each solve the Diagnostics panel shows the equilibrium residual for all six components; values below 1e-6 of the applied load mean the assembly and the solution are consistent.

The same model can be analysed for free vibration: the eigenvalues of K·φ = ω²·M·φ, computed by subspace iteration on the reduced (free) DOFs. Each mode gives the circular frequency ω [rad/s], the frequency f = ω/2π [Hz] and the natural period T = 2π/ω [s]. In 3D every member contributes axial, torsional (rotary inertia ρ·(Iy+Iz)) and biaxial bending mass terms.

Mass inputWhereMeaning
Self mass ρ·Aautomatic density of the material × area of the section, always included
Node mass [kg]Properties of the node, or the Nodes table concentrated mass on the node: equipment, tank, slab as a point mass
Member added mass [kg/m]Properties of the member, or the Members table distributed mass over the self mass: finishes, cladding, services

Press Compute modes in the Modal analysis panel (or Modes in the bar) and read the Modes (modal) table: ω, f, T, the participation factors Γx/Γy/Γz and the effective modal masses in % of the total mass, with the cumulative value per direction. Select a mode to draw its shape; Animate mode makes it move.

The mode shapes are normalised to φᵀ·M·φ = 1 and drawn scaled to about 12 % of the model span. One member is one element, so frequencies converge from above; refine long members into a few sub-members for the exact beam value. A vertical cantilever of 8 elements reproduces f₁ = (3.516/2π)·√(EI/ρAL⁴) to about 2×10⁻⁶, and a planar model with the out-of-plane DOFs restrained gives exactly the 2D frequencies (verified in tools/fea_modal_check.js).

Reading a 3D modal table

Typical values with the models shipped in fea3d/examples: the 6 × 6 m demo frame (h = 4.00 m, mass 2 756 kg) gives T₁ = 0.4109 s (f₁ = 2.433 Hz) as a degenerate X/Y pair, and the tower gives T₁ = 0.1717 s (f₁ = 5.82 Hz).

Undamped, linear, consistent masses — no damping ratios, no response spectrum and no time history. Editing the model (geometry, sections, masses) clears the modal results.

The element itself — shape functions, stiffness and load matrices, static condensation of the releases, the consistent mass matrix and the subspace iteration — is derived in the theory note The Finite Element Method for Frames, together with the checks against closed-form solutions and against a commercial program.

11 · Check it by hand

Three closed-form cases that the solver reproduces to machine precision (they are also automated in tools/fea3d_check.js):

CaseModelExpected
Axial bar L = 2.00 m, A = 100 cm², E = 210 000 N/mm², fixed at one end, Fx = 100 kN u = FL/EA = 0.0952 mm
Cantilever, vertical load L = 2.00 m, Iz = 340 cm⁴, P = 10 kN at the tip w = PL³/(3EIz) = 0.373 mm
Torsion L = 2.00 m, J = 210 cm⁴, G = 80 770 N/mm², Mx = 5 kNm at the tip θx = TL/(GJ) = 0.590 mrad

A simply supported beam with q = 10 kN/m over 6.00 m gives ΣRz = 60 kN, Mmax = qL²/8 = 45 kNm and a mid-span deflection 5qL⁴/(384EIz). The same portal frame modelled in 3D with the out-of-plane DOFs restrained reproduces the FEA Solver 2D results exactly.

Modal check (frequency and period)

Build a cantilever 6.00 m long out of eight members (nodes every 0.75 m, the first one fixed with all six DOFs), with A = 20 cm², Iy = Iz = 1000 cm⁴, J = 2000 cm⁴, E = 210 000 N/mm², ρ = 7850 kg/m³, then press Modes:

CaseFormulaExpected
First bending (both planes, Iy = Iz) f₁ = (3.516/2π)·√(EI/ρAL⁴) 5.685 Hz → T₁ = 0.1759 s, modes 1 and 2 identical (degenerate pair)
Second bendingf₃ ≈ 6.267·f₁35.6 Hz
Model consistencythe same beam in FEA Solver 2D identical frequencies (checked to 10⁻¹⁴ in tools/fea_modal_check.js)

Because Iy = Iz the cantilever bends at the same frequency in the local x-y and x-z planes, which is exactly the degenerate pair a symmetric structure produces — a good way to see how the table reports it: two identical f values, one mode vibrating in one plane and the other in the perpendicular plane (in the 2D module only one of the two exists).

Cross-check against Autodesk Robot Structural Analysis

The example fea3d/examples/robot-mast-3d.json is a real project (model Muntele Gaina: a 120-node, 340-bar lattice mast, 12 sections — circular tubes and equal angles — fixed at 4 base nodes, with self weight, a permanent nodal load and a wind case, plus the ULS/SLS combinations) imported from a Robot printout and solved here. The reproduction is automated:

node tools/robot_import.js "informatii documente de creat/exemplu robot.html"

The script reads the Robot report, writes the JSON model and compares every reaction and displacement with the values printed by Robot:

Quantity (5 cases / combinations)RobotFEA Solver 3D Deviation
Σ vertical reactions, DL1 (self weight)138.36 kN138.34 kN 0.02 %
Σ vertical reactions, COMB1 (ULS)197.56 kN197.56 kN 0.00 %
Peak horizontal displacement, COMB1537.5 mm537.8 mm 0.06 %
Largest reaction component (FZ, node 11, COMB1)−1561.1 kN −1559.9 kN0.08 %
Axial forces, envelope of 340 bars−1297.7 kN−1292.2 kN 0.37 % of the peak

Every reaction (20 node/case pairs) and every displacement (600 node/case triplets) was compared: forces agree to 0.07 % and translations to 0.10 % of their peak, bending moments and rotations to about 1.7 % (small quantities: 4 kNm, 1°). The residual difference is expected and comes from the element formulation — Robot includes shear deformation (its sections carry Ay/Az), while this solver uses Euler–Bernoulli, so it is slightly stiffer.

12 · Limits and assumptions

13 · Differences from FEA Solver 2D

FEA Solver 2DFEA Solver 3D
Degrees of freedom3 per node6 per node (12 per member)
SectionsA, Iy, IzA, Iy, Iz, J
ResultsN, V, MN, Vy, Vz, Mx, My, Mz
Modal analysisX and Y participation X, Y and Z participation, torsional rotary inertia
Loads on memberglobal / local transverseglobal X/Y/Z, local x/y/z
Viewfixed plane, pan/zoomorbit / pan / zoom, 4 presets
Everything elsesame layout, same units, same JSON idea, same load cases, combinations and diagnostics

The two solvers are independent applications: FEA Solver 2D has not been modified. A 2D model cannot be opened here unchanged (it has no Z coordinates and no J), which is why the 3D tool ships its own examples and its own JSON format (version: 3).