Bolt Calculator - Eurocode 3 (EN 1993-1-8)

Calculate bolt capacity for tension, shear, bearing and combined loading

Bolt Properties
EN 1993-1-8 §3.6.1 — Tension capacity
Ft,Rd=k2⋅fub⋅AsγM2
k2 = 0.9 (non-counterbored). Bearing of the plate is checked separately: Fb,Rd = k1·αb·fu·d·t / γM2.
Select bolt diameter according to ISO metric thread
First number: tensile strength/100 (MPa), Second: yield ratio
Load, Plate & Safety Factors
kN
Design force acting on the bolt
Connected Plate Properties
mm
mm
mm
For bearing resistance calculation according to §3.6.1(3)
Partial Safety Factors (γM)
Default: 1.25 (EN 1993-1-8)
Default: 1.25 (EN 1993-1-8)
Bolt Material Properties
MPa
MPa
Calculation Results
No Calculation Yet

Enter bolt properties and load, then click "Calculate All Verifications"

Verification Result
Verification Pending

Calculation results will appear here

Eurocode Reference & Calculation Details

EN 1993-1-8:2005 - Design of steel structures - Part 1-8: Design of joints

Tension capacity: §3.6.1
Ft,Rd = k2 × fub × As / γM2

Shear capacity: §3.6.2
Fv,Rd = αv × fub × As × n / γM2

Bearing capacity: §3.6.1(3)
Fb,Rd = k1 × αb × fu × d × t / γM2

Combined loading: §3.6.1(4)
(Ft,Ed/Ft,Rd)² + (Fv,Ed/Fv,Rd)² ≤ 1.0

Safety factors: §2.2
Romanian National Annex recommends γM2 = 1.25

Tips & Information
Bolt Sizes
  • M8: As = 36.6 mm²
  • M10: As = 58.0 mm²
  • M12: As = 84.3 mm²
  • M16: As = 157.0 mm²
  • M20: As = 245.0 mm²
Bolt Grades
  • 4.6: fub = 400 MPa
  • 5.6: fub = 500 MPa
  • 8.8: fub = 800 MPa
  • 10.9: fub = 1000 MPa
Safety Factors
  • γM2: Resistance of bolts = 1.25
  • γM2: Resistance of plates = 1.25
  • Check National Annex for country-specific values
  • For preloaded bolts: γM3 = 1.25
Combined Loading
  • Interaction formula according to §3.6.1(4)
  • Both tension and shear must be considered
  • Utilization must be ≤ 1.0
  • Point must be inside interaction curve