ADG Bolt Calculatoruser guide Back to the calculator Back to ADG

Bolt calculator – user guide

Resistance of one bolt (or one bolt row) in a bolted connection according to EN 1993-1-8: tension, shear in one or two planes, bearing on the plate, and the interaction between tension and shear. Every number below is what the page actually computes.

1. What the calculator does

For a chosen bolt (metric size and property class), plate (thickness, steel grade, edge and pitch distance) and load, the calculator returns the design resistances Ft,Rd, Fv,Rd and Fb,Rd, the utilisation of the applied force against each of them, and a pass/fail verdict for the whole set of verifications.

The formulas and partial factors follow EN 1993-1-8:2005 with the Romanian National Annex values as defaults: γM2 = 1.25.

Scope: one bolt, one plate thickness, one load direction. The connection as a whole (group of bolts, net section of the plate, block tearing, prying, slip-resistant categories B/C, welds) is not covered — see §9.

2. Quick start

  1. Bolt Size — pick the metric size (M8 … M36). The tensile stress area As is filled in automatically.
  2. Bolt Grade — 4.6, 5.6, 8.8 or 10.9; fub and fyb follow, and both stay editable.
  3. Loading Type — Tension, Shear (1 plane), Shear (2 planes) or Combined.
  4. Applied Force FEd — the design force in the bolt, in kN.
  5. Plate — thickness t, material (S235 … S460), edge distance e1 and pitch p1 (parallel to the load, used for bearing).
  6. Press Calculate All Verifications; the two lower panels show the intermediate values and the verdict.

Reset to Default Values restores the reference input set (M10, 8.8, 10 kN, t = 10 mm, S355, e1 = 30 mm, p1 = 60 mm).

3. Inputs

InputUnitMeaning / notes
Bolt Size–M8, M10, M12, M16, M20, M24, M30, M36 → As = 36.6, 58.0, 84.3, 157, 245, 353, 561, 817 mm²
Bolt Grade–4.6 (400/240), 5.6 (500/300), 8.8 (800/640), 10.9 (1000/900): fub/fyb in MPa
Loading Type–Tension / Shear 1 plane / Shear 2 planes / Combined (tension + shear)
Applied force FEdkNDesign force on the bolt
Plate thickness tmmThickness of the ply used for bearing
Plate material–S235 (235/360), S275 (275/430), S355 (355/510), S420 (420/540), S460 (460/550): fy/fu
Edge distance e1mmBolt centre to plate edge, in the load direction
Pitch p1mmCentre-to-centre spacing in the load direction
γM2 (shear/bearing)–Default 1.25
γM2 (tension)–Default 1.25; separate field, so the tension side can be adjusted independently
fub, fybMPaBolt strengths; prefilled from the grade, editable
The hole diameter is taken as d0 = d + 1 mm (normal clearance hole). For a larger hole (slotted, oversize) compute the bearing resistance by hand.

4. The four resistances

Tension — EN 1993-1-8 §3.6.1

Ft,Rd = k2 · fub · As / γM2 with k2 = 0.9

Shear — EN 1993-1-8, Table 3.4

Fv,Rd = αv · fub · As · n / γM2 αv = 0.6 (4.6 / 5.6 / 8.8) · αv = 0.5 (10.9) · n = 1 or 2 shear planes

The shear plane passes through the threaded part, which is why As is used and not the shank area.

Bearing — EN 1993-1-8, Table 3.4

Fb,Rd = k1 · αb · fu · d · t / γM2 αb = min( e1 / (3 d0) ; p1 / (3 d0) − 0.25 ; fub / fu ; 1.0 ) k1 = min( 2.8 e1 / d0 − 1.7 ; 2.5 )

Bearing is computed per shear plane and multiplied by the number of planes, so a double-shear connection shows the sum of both plies.

k1 depends on the edge distance perpendicular to the load, e2; the page has one edge-distance field and uses e2 = e1. That is safe for a square pattern — reduce k1 by hand if your e2 is smaller.

5. Reading the results

The Calculation Results panel repeats every intermediate quantity and the formula with the numbers inserted, so the calculation can be checked line by line. The Verification Result panel gives:

  • a green ALL VERIFICATIONS PASS ✓ or a red VERIFICATION FAILS ✗ banner;
  • the utilisation factors, coloured by level (green < 0.8, amber < 1.0, red ≥ 1.0);
  • when a check fails, the list of the values that exceed 1.0 and by how much.

In tension mode only Ft,Rd governs; in shear mode both Fv,Rd and Fb,Rd are checked and the lower one governs; in combined mode all three.

6. Combined tension and shear

With Loading Type = Combined the page shows an extra tension–shear interaction diagram and evaluates the interaction as an ellipse:

√( (Ft,Ed / Ft,Rd)² + (Fv,Ed / Fv,Rd)² ) ≤ 1.0
Note for code checking. EN 1993-1-8, Table 3.4 gives a linear interaction for bolts of class 8.8 and 10.9: Fv,Ed/Fv,Rd + Ft,Ed/(1.4 Ft,Rd) ≤ 1.0. The ellipse used here is more conservative in the middle of the range, but it is not the code expression — when the result is close to 1.0, verify the linear form by hand.

7. Export and history

ActionWhat it does
Export to PDFRe-renders the page in print layout (?export=pdf) with inputs, formulas and verdict; choose Save as PDF in the print dialog.
Export as TextDownloads a plain-text calculation sheet with all inputs, intermediate values and the verdict.
Print CalculationOpens the print dialog for the current page.
Clear HistoryEmpties the list of previous calculations kept in the browser (localStorage) on this device.

Nothing is sent to a server: the calculation runs in the browser and the history stays on your computer.

8. Check it by hand

Reference input set of the page: M10, class 8.8, FEd = 10 kN, t = 10 mm, S355, e1 = 30 mm, p1 = 60 mm, γM2 = 1.25.

StepValue
d0 = d + 111 mm
αb = min(30/33 ; 60/33 − 0.25 ; 510/800 ; 1.0)min(0.909 ; 1.568 ; 0.637 ; 1.0) = 0.637
k1 = min(2.8·30/11 − 1.7 ; 2.5)2.50
Ft,Rd = 0.9 · 800 · 58.0 / 1.2533.4 kN
Fv,Rd (2 planes) = 0.6 · 800 · 58.0 · 2 / 1.2544.5 kN (22.3 kN per plane)
Fb,Rd = 2.5 · 0.637 · 510 · 10 · 10 / 1.2565.0 kN per plane
Utilisation in tension10 / 33.4 = 0.299

These are exactly the values the page shows for the default input set.

9. Limits and assumptions

  • One bolt at a time. A bolt group must be distributed by the user (rigid plate, elastic or plastic distribution); the engineering note on eccentric bolt groups shows how the distribution changes the force in the outer bolt.
  • No block tearing (EN 1993-1-8 §3.10.2), no prying action, no wedge washers, no packings, no long joints.
  • No slip resistance — categories B and C (preloaded bolts, Fs,Rd) are not implemented.
  • Plate net section and the plate's own tension capacity are not checked; only the bolt and the local bearing are.
  • Tension–shear interaction is the ellipse of §6, not Table 3.4.
  • Partial factors default to the Romanian NA (γM2 = 1.25); change the fields for another National Annex.

The calculator is a design aid, not a substitute for the code text or for the engineer's judgement. Always check the printed calculation against EN 1993-1-8:2005 before issuing it.