Eccentric Out-of-Plane Bolt Groups: Elastic and Plastic Force Distribution
1. Introduction
Bolt groups subjected to out-of-plane loading are frequently encountered in steel connections in which a plate is fastened to a supporting member and loaded normal to its plane. In such configurations, the external action is not transmitted to the fasteners solely through direct shear or direct tension. Because the resultant load is generally eccentric with respect to the centroid of the bolt group, a moment is induced about an axis lying in the plane of the plate. The fasteners are therefore required to resist a combination of direct force and force components generated by rotation of the connection.
The analysis of this load condition is complicated by the fact that the force distribution among the fasteners depends on assumptions that are not uniquely defined by static equilibrium. For a rigid plate, the deformation of the plate is neglected, and the fastener forces are derived from a prescribed kinematic condition, namely the location of the centre of rotation. The classical treatment assumes rotation about the centroid of the bolt group and adopts a linear elastic relationship between fastener deformation and fastener force. This approach leads to the familiar expression
in which F is the applied force, n is the number of fasteners, M is the moment about the assumed centre of rotation, and yi is the distance of fastener i from the corresponding axis. Although this expression is widely used, it is based on a kinematic assumption that may be inconsistent with the actual boundary conditions of the connection. In particular, it ignores the possibility of contact between the plate and the supporting member and therefore neglects the compression zone that may develop at the edge of the plate. Consequently, the centroidal formula does not necessarily represent the most unfavourable or the most realistic distribution of forces in an eccentrically loaded bolt group.
Alternative rigid-plate assumptions may be adopted by selecting different centres of rotation. Rotation about the bottom row of bolts represents a refinement in which the lower fasteners are treated as the immediate rotational restraint, whereas rotation about the bottom compression edge represents a kinematic condition in which the plate bears against the support along its lower boundary. Each assumption alters the lever arms and therefore modifies the calculated force in the most heavily loaded fastener. The resulting differences are not merely mathematical; they reflect different interpretations of the physical interaction between the plate, the fasteners, and the supporting member.
In addition to the ambiguity associated with the centre of rotation, the actual behaviour is influenced by the flexibility of the plate. A real base plate is not perfectly rigid. Under out-of-plane loading, flexural deformation of the plate may cause the edge of the plate to bear against the support, producing a prying action that introduces additional tensile forces in the adjacent fasteners. This effect is not captured by rigid-plate theory and generally leads to fastener forces higher than those predicted by purely equilibrium-based elastic models. The discrepancy is particularly relevant for the outermost fasteners, which are often the most severely loaded components of the connection.
At the ultimate limit state, the assumption of linear elastic behaviour becomes increasingly inadequate. Yielding of the plate or of the fasteners allows a redistribution of internal forces, and the load path may change significantly compared with the elastic regime. The component method of EN 1993-1-8 provides a framework for evaluating the resistance of individual components and for accounting for ductility and redistribution. However, the transition from elastic force distribution to plastic redistribution requires a clear understanding of the kinematic and mechanical assumptions adopted in the analysis.
The objective of the present article is to analyse how different kinematic assumptions regarding the centre of rotation, together with the distinction between elastic and plastic material behaviour, affect the force in the most heavily loaded fastener of an eccentrically loaded out-of-plane bolt group. A representative connection is examined, and the fastener forces are calculated for three elastic centres of rotation: the bolt group centroid, the bottom row of bolts, and the bottom compression edge. The limitations of rigid-plate theory are then discussed with reference to plate flexibility and prying action, and the implications of plastic redistribution at the ultimate limit state are considered. On this basis, the engineering consequences of the choice of analysis model are assessed, and the conditions under which classical centroidal formulae may lead to unconservative predictions are identified.
2. Problem Statement & Geometry
The connection considered in the present analysis consists of a rectangular base plate fastened to a supporting member by means of a group of six bolts. The base plate has a width of 300 mm, a height of 400 mm, and a thickness of 15 mm, and is made of steel grade S235. The fasteners are six M20 bolts of property class 8.8, arranged in two vertical columns and three horizontal rows. The bolt positions are measured from the bottom edge of the plate, which is taken as the reference line y=0. The three rows are equally spaced at 150 mm and are located at

This arrangement is symmetric with respect to the mid-height of the plate: the distance from the bottom edge to the first row is 50 mm, and the distance from the third row to the top edge is 400−350=50 mm. The two columns are arranged symmetrically with respect to the vertical centreline of the plate. Since the eccentricity of the applied load is defined only in the y-direction, the column spacing does not enter the force distribution for rotation about a horizontal axis and is therefore not required for the present analysis.
The centroid of the bolt group coincides with the mid-height of the bolt arrangement:
The applied action is a point load F=45 kN acting perpendicular to the plane of the plate, i.e. in the out-of-plane direction. The load is applied at the upper edge of the plate, at a height
The load is therefore eccentric with respect to the centroid of the bolt group. The eccentricity is
The load thus acts 200 mm above the centroid of the bolt group. The resulting moment about the centroidal axis of the bolt group is
For the alternative kinematic assumptions analysed in Section 3, the corresponding moments are obtained by taking the lever arm from the respective centre of rotation. For rotation about the bottom row of bolts at y=50 mm, the lever arm is
and the moment is
For rotation about the bottom compression edge at y=0, the lever arm is
and the moment is
It is noted that the eccentricity adopted here, e=200 mm, is substantially larger than the value typical of compact base-plate connections. This is intentional. A large eccentricity amplifies the differences between the kinematic assumptions examined in Section 3 and, in particular, exposes a fundamental deficiency of the classical centroidal formula: for sufficiently large e, the linear elastic distribution obtained from rotation about the bolt group centroid yields a compressive force in the bottom row of fasteners. Since a bolt cannot transmit compression to the plate through tension, the centroidal model becomes physically inadmissible in that regime. The present geometry therefore provides a rigorous test case for the comparative analysis that follows.
The material and fastener properties adopted for the subsequent calculations are summarised as follows. For the S235 plate steel, the nominal yield strength is fy=235 MPa and the nominal ultimate strength is fu=360 MPa. For the M20 bolts of class 8.8, the nominal yield strength is fyb=640 MPa, the nominal ultimate strength is fub=800 MPa, and the tensile stress area is As=245 mm2.
The problem addressed in the following sections is the determination of the force in the most heavily loaded fastener under different kinematic assumptions for the centre of rotation. Three elastic rigid-plate assumptions are examined: rotation about the bolt group centroid at y=200 mm, rotation about the bottom row of bolts at y=50 mm, and rotation about the bottom compression edge at y=0. These assumptions are compared with respect to the resulting fastener forces, and the limitations of rigid-plate theory are subsequently discussed with reference to plate flexibility, prying action, and plastic redistribution at the ultimate limit state.
3. Elastic Analysis: The Three Centers of Rotation
The elastic analysis of an eccentrically loaded bolt group is conventionally based on the assumption that the plate behaves as a rigid body and that the fasteners deform linearly with the applied force. Under these conditions, the force in fastener i is expressed as the superposition of a direct component, associated with the translation of the plate, and a rotational component, associated with the rotation of the plate about a prescribed axis. For rotation about an axis located at y=yc, the fastener force is written as
where yi′=yi−yc is the distance of fastener i from the assumed axis, Mc=F(yF−yc) is the moment of the applied load about that axis, and the summation extends over all n=6 fasteners. The denominator ∑yi′2 is taken over the six bolts, i.e. each row contributes twice.
The three kinematic assumptions examined below differ only in the value of yc. It is emphasised at the outset that the choice of yc is not arbitrary from the standpoint of equilibrium; this point is examined critically in Section 3.4.
3.1 Rotation about the bolt group centroid (yc=200 mm)
The centroid of the bolt group coincides with the second row, so that yc=ȳ=200 mm. The distances of the three rows from the centroidal axis are
The sum of the squared distances over the six fasteners is
The moment about the centroid is M=9000 kN⋅mm, as derived in Section 2. The direct component is
The rotational component for the top row is
and the force in the top bolt is therefore
The force in the middle row is
and the force in the bottom row is
The negative sign indicates that the centroidal model predicts compression in the bottom row. This result is physically inadmissible: a bolt cannot transmit compression to the plate through tension, and the bottom row would, in reality, either separate from the support or be relieved of load by contact between the plate and the support in the compression zone. The centroidal model is therefore theoretically flawed for two reasons. First, it ignores the contact between the plate and the supporting member, which is the mechanism by which compressive actions are transmitted. Second, by enforcing a linear force distribution that is antisymmetric about the centroid, it can produce tensile and compressive forces of equal magnitude that are incompatible with the one-sided nature of the bolt–plate interaction.
It is noted that the centroidal model does satisfy global equilibrium. The direct components sum to 6×7.5=45 kN, and the rotational components sum to zero because ∑yi′=0. The moment about the centroid is
which equals M. The model is thus internally consistent but physically inadmissible, and this distinction is central to the subsequent discussion.
3.2 Rotation about the bottom row of bolts (yc=50 mm)
A refined rigid assumption is obtained by taking the bottom row of bolts as the axis of rotation. The rationale is that, once the bottom row is relieved of compression by contact, the plate may be regarded as pivoting about this row, with the bottom fasteners acting as the immediate rotational restraint. The moment of the applied load about this new axis is, from Section 2,
The distances of the three rows from the new axis are
The sum of the squared distances is
The force in the top bolt becomes
The middle row gives
and the bottom row gives
Relative to the centroidal model, the force distribution is shifted markedly. The top-bolt force increases from 22.5 to 28.5 kN, an increase of approximately 27 %, while the bottom row changes from an inadmissible compression of −7.5 kN to a tension of 7.5 kN. The distribution is therefore physically admissible in the sense that all fasteners are in tension, and it reflects the intuition that rotation about a lower axis amplifies the force in the upper fasteners by increasing their lever arms.
It must be observed, however, that this calculation does not satisfy global equilibrium. The sum of the fastener forces is
which exceeds the applied load of 45 kN. The moment about the axis at y=50 mm is
which exceeds the applied moment M1=15750 kN⋅mm. The origin of the discrepancy is that the rotational term no longer sums to zero when the axis is not at the centroid: ∑yi′=900 mm≠0, so the rotational component acquires a net resultant equal to M1∑yi′/∑yi′2=63 kN. The direct component of 45 kN and this net rotational resultant of 63 kN together give the 108 kN obtained above.
The result must therefore be interpreted with care. The calculation illustrates how shifting the axis redistributes the force and, in particular, how it removes the inadmissible compression in the bottom row. It does not, however, constitute an equilibrium-consistent elastic solution. The physical meaning of this inconsistency is discussed in Section 3.4.
3.3 Rotation about the bottom compression edge (yc=0)
The third and most realistic rigid kinematic assumption places the axis of rotation at the bottom compression edge of the plate, yc=0. This corresponds to the physical situation in which the plate bears against the support along its lower edge and rotates about that contact line. The moment of the applied load about the bottom edge is, from Section 2,
The distances of the three rows from the bottom edge are simply their ordinates:
The sum of the squared distances is
The force in the top bolt is
The middle row gives
and the bottom row gives
The distribution is again entirely tensile and is more uniform than in the previous case: the ratio between the top and bottom rows is 26.59/10.23≈2.60, compared with 28.5/7.5=3.80 for rotation about the bottom row. This reflects the fact that the larger lever arm of the applied load is compensated by the larger spread of the fastener distances, so that the rotational component is distributed more evenly among the rows.
The equilibrium check again reveals a discrepancy. The sum of the fastener forces is
and the moment about y=0 is
compared with the applied moment M0=18000 kN⋅mm. As in the previous case, the inconsistency arises because ∑yi′=1200 mm≠0, so that the rotational term acquires a net resultant of M0∑yi′/∑yi′2=65.45 kN.
3.4 Comparison of the three assumptions
The forces in the most heavily loaded fastener, i.e. the top bolt, obtained under the three kinematic assumptions are summarised in Table 1.
Table 1. Force in the top bolt for the three elastic kinematic assumptions.
| Assumption | Axis yc (mm) | Moment about axis (kN·mm) | Ftop (kN) | Fbot (kN) | Physical admissibility |
|---|---|---|---|---|---|
| Centroidal | 200 | 9 000 | 22.50 | −7.50 | Compression in bottom row — inadmissible |
| Bottom row | 50 | 15 750 | 28.50 | 7.50 | All tension — admissible |
| Bottom edge | 0 | 18 000 | 26.59 | 10.23 | All tension — admissible |
Three observations follow from Table 1. First, the centroidal model predicts the lowest force in the top bolt, but it does so at the cost of predicting compression in the bottom row, which cannot be transmitted by the fasteners. The centroidal prediction is therefore not merely approximate; it is physically inadmissible for the geometry considered, and the magnitude of the top-bolt force cannot be regarded as a safe estimate.
Second, the bottom-row assumption produces the highest top-bolt force of the three, 28.5 kN, despite not having the largest moment about its axis. The reason is that placing the axis at the bottom row maximises the relative distance of the top bolt (300 mm out of a total spread of 300 mm) while the moment, though smaller than in the bottom-edge case, is distributed over a smaller base. The bottom-edge assumption gives a lower top-bolt force because the rotational component is spread over a larger lever arm.
Third, and most importantly, the comparison exposes a fundamental difficulty with the notion of a freely chosen centre of rotation in elastic analysis. The three calculations above do not all satisfy global equilibrium. The centroidal model satisfies equilibrium exactly but is physically inadmissible; the two shifted-axis models are physically admissible in the sense that all fasteners remain in tension, but they violate force and moment equilibrium because the rotational term acquires a net resultant when the axis is not at the centroid.
This difficulty admits a precise interpretation. For a rigid plate supported on linear elastic fasteners with no contact, the elastic solution is unique and is obtained by enforcing both force and moment equilibrium together with the kinematic constraint of a rigid-body displacement field. When this is done for the present geometry, the resulting centre of rotation is found to lie at y=125 mm, which lies above the bottom row and therefore implies compression in that row — a result that is again physically inadmissible. The elastic rigid-plate solution is thus internally inconsistent for the present connection, precisely because the connection cannot develop the compressive forces that the solution requires. Contact between the plate and the support must occur, and it is this contact that legitimises a shift of the effective centre of rotation away from the centroid.
The three kinematic assumptions examined above should therefore be understood not as three equally valid elastic solutions, but as three heuristic descriptions of a connection whose true behaviour is governed by contact. The bottom-row and bottom-edge assumptions are physically more plausible than the centroidal assumption because they respect the one-sided nature of the bolt–plate interaction, and they indicate that the force in the top bolt is likely to lie in the range 26–29 kN, appreciably higher than the 22.5 kN predicted by the centroidal formula. The spread between the shifted-axis predictions and the centroidal prediction is a measure of the uncertainty introduced by the rigid-plate idealisation itself.
The remaining sources of uncertainty — plate flexibility and prying action, on the one hand, and plastic redistribution at the ultimate limit state, on the other — are examined in Sections 4 and 5, respectively. Both act in the same direction as the shift of the centre of rotation considered here: they tend to increase the force in the outermost fastener beyond the value obtained from the centroidal elastic formula.
4. The Effect of Plate Flexibility (Prying Action)
4.1 Limitations of the rigid-plate idealisation
The analyses presented in Section 3 rest on the assumption that the base plate behaves as a rigid body. Under this assumption, the displacement of every point of the plate is described by a rigid-body motion, and the elongation of each fastener is a linear function of its distance from the assumed centre of rotation. The force distribution is thus determined exclusively by the kinematic constraint and by the geometry of the bolt pattern. Neither the flexural stiffness of the plate nor the axial stiffness of the fasteners enters the calculation.
This idealisation is convenient but cannot be exact. The applied load acts on the plate at y=400 mm, whereas the resisting forces are mobilised at the bolt rows. The load must therefore be transmitted to the fasteners through bending of the plate over a finite length. A plate of finite flexural stiffness E I deforms under this bending, and the magnitude of the deformation depends on the ratio between the plate stiffness and the axial stiffness of the bolts, kb=E As/Le, where Le is the effective grip length. Only in the limit E I→∞ does the rigid-plate result apply. For a 15 mm steel plate this limit is not approached, and the finite flexibility of the plate modifies the force distribution in a manner that the rigid-plate model cannot represent.
Two further limitations follow from the rigid-plate assumption. First, the assumption cannot represent the one-sided nature of the contact between the plate and the supporting member: the plate may bear against the support where it is pressed towards it, but it cannot pull on the support where it separates. Second, the assumption provides no information on the local distribution of pressure at the interface, and it therefore cannot capture the concentration of bearing pressure that develops in the immediate vicinity of a bolt.
4.2 The prying mechanism
The most important consequence of plate flexibility is the phenomenon known as prying action. It is most clearly described with the aid of the classical T-stub idealisation, in which a flange is bolted to a rigid support and loaded by a stem force F applied at a distance b from the bolt line. When the stem force is applied, the flange bends about the bolt line. If the flange extends beyond the bolt line by a distance a, the toe of the flange bears against the support, and a contact reaction Q is developed at the toe. Equilibrium of the T-stub then requires
where B is the tension in each of the two bolts and Q is the prying force at each toe. The force in the bolt is therefore larger than the share of the external load that would be obtained from a rigid-flange analysis. The additional force Q is the prying force.
The magnitude of Q is governed by the compatibility of deformation between the flange and the bolts. A flexible flange deforms readily about the bolt line and therefore develops a larger prying force; a stiff flange or a short toe distance a limits the prying force. The prying force also depends on the ratio a/b: a small a (toe close to the bolt) and a large b (stem far from the bolt) favour prying, because the flange is then able to lever against the toe with a short, stiff lever arm. In the limit of a very stiff flange or a very small toe distance, the prying force tends to zero and the rigid-flange result is recovered.
It is essential to recognise that prying is a contact phenomenon. The prying force Q exists only if the toe of the flange is in contact with the support. If the toe separates, Q vanishes and the bolt force reverts to its rigid-flange value. The prying force is therefore self-limiting: it can develop only as long as the contact at the toe is maintained.
4.3 Prying in the present connection
In the connection analysed here, the role of the T-stub stem is played by the applied load at y=400 mm, and the role of the flange is played by the portions of the base plate that extend beyond each bolt row. The geometry provides two distinct regions in which the interaction between plate bending and contact must be considered.
At the bottom row, the plate extends 50 mm below the bolt line to the bottom edge at y=0. When the load at the top of the plate pulls the upper part of the connection away from the support, the plate tends to rotate about a region in the lower part of the connection, and the bottom edge of the plate is pressed against the support. The bottom edge therefore acts as a toe, and a prying reaction is developed there. The bottom-row bolts carry both their share of the external tension and the prying force transmitted from the toe. With a toe distance a=50 mm and a stem distance b=150 mm to the adjacent row, the ratio a/b is of a magnitude at which prying forces are known to be significant for plates of ordinary thickness.
At the top row, the plate extends 50 mm above the bolt line to the top edge at y=400, where the load is applied. This configuration is less favourable to classical prying at that location: the load acts at the free edge itself, so that the plate above the bolt line is loaded rather than restrained, and the free edge moves away from the support rather than bearing upon it. No toe is available above the top row, and the prying action at this row is therefore not a toe-bearing mechanism in the classical sense. The plate between the top row and the middle row is likewise pulled away from the support over most of its length, so that contact between these rows is not developed.
The two regions are nevertheless coupled through the global kinematics of the connection. The contact pressure that develops at the bottom edge is the physical origin of the shift of the centre of rotation discussed in Section 3. The bottom-edge prying reaction and the "compression edge" of Section 3.3 are two descriptions of the same contact phenomenon: the former is expressed in terms of the local flange equilibrium, the latter in terms of the global kinematics of the connection. The bottom-row assumption of Section 3.2 represents an intermediate idealisation, in which the contact is assumed to be concentrated at the bolt line rather than distributed over the edge.
4.4 Consequence for the most heavily loaded fastener
Prying action increases the force in the fasteners beyond the value obtained from a purely rigid-plate elastic analysis, but the manner in which it does so differs between the two regions identified above.
For the bottom row, the effect is direct. The bolts adjacent to the bearing edge must carry the prying force transmitted from the toe in addition to their share of the external load, in accordance with the T-stub equilibrium 2B=F+2Q. The force in the bottom-row bolts is therefore higher than the values of 7.5 to 10.2 kN obtained from the rigid analyses of Section 3. Design guidance based on the T-stub model indicates that prying forces of the order of 20 % to 40 % of the bolt force are common for connections of comparable flexibility, although the exact value depends on the detailed geometry and on the degree of plastification of the plate.
For the top row, which is the most heavily loaded row in the elastic range, the effect is indirect but no less important. Since no toe is available above the top row, the top-bolt force is not increased by a local prying reaction at that location. It is increased, instead, by the global consequence of the bottom-edge contact: the contact constrains the lower part of the connection against separation, forces the connection to rotate about a lower axis, and thereby increases the lever arm of the applied load relative to the tension zone. This is precisely the effect captured, in an idealised form, by the bottom-row and bottom-edge assumptions of Sections 3.2 and 3.3. The rigid-plate calculations with a shifted axis therefore already contain part of the prying effect, in the sense that the shift of the axis is a global manifestation of the contact that prying produces locally.
A second contribution must also be recognised for the top row. The plate between the top row and the applied load acts as a short cantilever, and its flexibility concentrates the transmitted force in the immediate vicinity of the top bolts. The rigid-plate model, by enforcing a linear force distribution across the whole bolt group, smooths this concentration and therefore underestimates the peak force in the outermost fastener. This effect is distinct from toe-bearing prying, but it is a direct consequence of the same plate flexibility and acts in the same direction.
When the two contributions are considered together, it must be concluded that the force in the top bolt predicted by the centroidal formula, 22.5 kN, is a lower bound on the actual force rather than a reliable estimate. The shifted-axis calculations of Section 3 give 26.6 to 28.5 kN, and the additional local effects associated with plate flexibility are expected to raise the actual force further. A force of the order of 30 kN or more in the top bolt is therefore plausible, corresponding to an increase of approximately 30 % over the centroidal prediction. This conclusion is qualitative, but the direction and order of magnitude of the effect are unambiguous: the centroidal formula does not capture the prying mechanism and cannot be relied upon as a safe estimate for the outermost fastener.
4.5 Prying as a contact nonlinearity
The prying force is not unlimited. As the applied load increases, the bending moment at the toe of the plate increases, and the plate eventually yields at the toe. Once the toe yields, the plate can no longer develop the full elastic prying force, and the prying force is reduced. In the limit state, the prying force is bounded by the plastic moment capacity of the plate section at the toe, and the bolt force is correspondingly bounded. This plastification of the toe provides a ductile reserve that is not available in the elastic range, and it is the basis on which prying action is treated in plastic design methods.
The description given in this section is elastic. A rigorous treatment of prying action requires either an iterative elastic analysis accounting for the one-sided contact at the interface, or a plastic analysis based on the component method. Both approaches are examined in Section 5, where the transition from elastic prying to plastic redistribution is considered.
5. Plastic Distribution
5.1 From elastic incompatibility to plastic redistribution
The elastic analyses of Section 3 revealed a fundamental difficulty: the rigid-plate solution that satisfies global equilibrium exactly, namely rotation about the centroid, is physically inadmissible because it requires compression in the bottom row of fasteners. The shifted-axis solutions, which are physically admissible in the sense that all fasteners remain in tension, do not satisfy equilibrium. The elastic rigid-plate idealisation is therefore internally inconsistent for the present connection, and this inconsistency is resolved only when contact between the plate and the support is admitted.
At the ultimate limit state, a further mechanism becomes available: plastic deformation. When the most heavily loaded component — whether the plate in bending, the plate in bearing, or the bolt in tension — reaches its yield capacity, it can deform plastically without a proportional increase in force. This permits a redistribution of internal forces from the yielded component to the components that retain reserve capacity. The resulting force distribution is no longer governed by the elastic stiffness ratios but by the relative plastic capacities of the components and by the kinematic mechanism that develops.
This distinction is central to the difference between elastic and plastic design. In elastic design, the force in each fastener is determined by compatibility of deformation, and the most heavily loaded fastener governs the design. In plastic design, the force distribution is determined by equilibrium and by the condition that no component is loaded beyond its plastic capacity, with the additional requirement that the connection possesses sufficient rotation capacity to mobilise the redistribution. The plastic resistance of the connection may therefore exceed the load at which the first component yields, and the ratio between the two is a measure of the available ductility and redistribution capacity.
5.2 The component method of EN 1993-1-8
The component method provides a systematic framework for evaluating the resistance of bolted connections at the ultimate limit state. In this method, the connection is decomposed into a set of basic components, each with a defined force–deformation or force–resistance characteristic. For a connection loaded out-of-plane, the relevant components include the bolts in tension, the plate in bending, the plate in bearing, and the contact between the plate and the support. The resistance of the joint is governed by the component with the lowest capacity, and the force distribution among the components is obtained from equilibrium and from the assumption of a plastic distribution of forces among the bolt rows in tension.
The component method is implemented in EN 1993-1-8 and is based on extensive experimental and analytical research, notably on the T-stub model for the plate in bending and on the characterisation of bolts in tension and shear. For the tensile zone of a connection with multiple bolt rows, the standard permits the assumption of a plastic distribution of forces, in which the bolt rows are assumed to carry forces proportional to their plastic capacities rather than to their elastic stiffnesses. This assumption is justified when the plate and the bolts possess sufficient ductility to allow the necessary redistribution.
Applied to the present connection, the component method identifies two competing failure modes for the tensile zone. The first is yielding of the plate in bending at the bottom edge, which corresponds to the formation of a plastic hinge at the toe and limits the prying force that can be developed. The second is tension failure of the top-row bolts, which corresponds to the exhaustion of the tensile capacity of the most heavily loaded fasteners. The governing mode is the one that occurs at the lower load, and the design resistance is correspondingly determined.
5.3 Plastic mechanisms and the shift of the load path
The transition from elastic to plastic behaviour changes the load path in three distinct ways.
First, the plastification of the plate at the bottom edge limits the prying force. As discussed in Section 4, the prying force Q is bounded by the plastic moment capacity of the plate section at the toe. Once this capacity is reached, further applied load is carried primarily by increased bolt tension rather than by increased prying reaction. The bottom-row bolts therefore cease to attract additional prying force, and the incremental load is transferred preferentially to the upper rows. This constitutes a redistribution of force from the bottom row towards the top row.
Second, the yielding of the plate in the vicinity of the top row changes the local load path. If the plate yields between the applied load and the top row, the force transmitted to the top bolts becomes limited by the plastic capacity of the plate section, and the connection may fail by plate yielding rather than by bolt fracture. Conversely, if the plate remains elastic in this region while the bolts yield, the top bolts reach their ultimate tensile capacity and the connection fails by bolt fracture. The relative capacities of the plate and the bolts therefore determine which component governs and how the force is distributed at failure.
Third, the plastification of the bolts themselves introduces a further redistribution. Once a bolt yields in tension, it can deform plastically at approximately constant force, allowing the adjacent bolts to attract a larger share of the applied load. This is the basis of the plastic distribution assumption in the component method: the bolt rows are assumed to carry forces up to their plastic capacities, and the total tensile resistance is the sum of these capacities rather than the sum of the elastic force components.
For the present geometry, the elastic analyses of Section 3 gave top-bolt forces in the range 22.5 to 28.5 kN. The tensile resistance of a single M20 bolt of class 8.8 is
where γM2=1.25 is the partial factor for resistance of bolts. The elastic top-bolt forces are therefore well below the bolt tensile resistance, and the bolts are not the governing component in the elastic range. The governing component is more likely to be the plate in bending at the bottom edge, where the prying action concentrates the bending moment over a short lever arm.
At the ultimate limit state, the plastic resistance of the plate at the bottom edge may be estimated from the T-stub model. The plastic moment capacity per unit width of the 15 mm S235 plate is
For a toe distance of 50 mm, the plastic resistance of the plate per bolt is of the order of Mpl/a=264 N⋅mm/mm per unit width, and the corresponding prying force is limited by this capacity. A detailed T-stub calculation according to EN 1993-1-8 would be required to determine the exact resistance, but the order of magnitude indicates that the plate capacity is comparable to the applied forces and may govern the design.
5.4 Elastic versus plastic design: implications for the present connection
The comparison between elastic and plastic design for the present connection can be summarised as follows.
In elastic design, the force in the top bolt is determined by the assumed centre of rotation. The centroidal formula gives 22.5 kN, but this value is physically inadmissible because it implies compression in the bottom row. The shifted-axis assumptions give 26.6 to 28.5 kN, which are physically plausible but do not satisfy equilibrium. The elastic rigid-plate approach is therefore inherently ambiguous for this connection, and the choice of the centre of rotation has a direct influence on the calculated force in the most heavily loaded fastener.
In plastic design, the ambiguity is resolved by the requirement that the connection develop a kinematically admissible mechanism at the ultimate load. The force distribution is determined by the plastic capacities of the components and by the condition that the external work equals the internal work dissipated in the plastic hinges and in the yielded bolts. The resulting resistance may be higher than the elastic limit, because the plastic reserve of the components is mobilised. Research on eccentrically loaded bolt groups has shown that the ultimate capacity can be approximately 30 % higher than the elastic limit, with the exact value depending on the ductility of the fasteners and on the geometry of the group.
For the present connection, the practical implication is that the force in the top bolt at the ultimate limit state is likely to be governed by the plastic capacity of the plate at the bottom edge and by the tensile capacity of the top bolts. The elastic calculations of Section 3 provide a useful indication of the force distribution, but they cannot be used directly to determine the ultimate resistance. A component-based check according to EN 1993-1-8 is required, in which the T-stub resistance of the plate at the bottom edge is compared with the tensile resistance of the top-row bolts, and the governing mode is identified.
5.5 Summary of the plastic behaviour
Three conclusions follow from the plastic analysis.
First, the plastic redistribution resolves the equilibrium inconsistency of the elastic rigid-plate model. The contact at the bottom edge, which is the physical origin of the shift of the centre of rotation, is also the location at which the first plastic hinge forms. The formation of this hinge limits the prying force and allows the incremental load to be transferred to the upper rows, in accordance with the plastic distribution assumption of the component method.
Second, the force in the most heavily loaded fastener at the ultimate limit state is not necessarily higher than the elastic prediction. If the plate yields at the bottom edge before the top bolts reach their tensile capacity, the top-bolt force may be limited by the plate capacity, and the connection may fail by plate yielding at a load lower than that corresponding to bolt fracture. Conversely, if the bolts are the governing component, the top-bolt force at failure is the bolt tensile resistance, which is considerably higher than the elastic force. The relative capacities of the plate and the bolts therefore determine whether the plastic redistribution is beneficial or whether it is limited by a brittle plate failure mode.
Third, the choice between elastic and plastic design has a direct influence on the interpretation of the results. Elastic design provides a conservative estimate of the force in the most heavily loaded fastener only if the assumed centre of rotation is physically admissible and if the prying action is accounted for. Plastic design provides a more realistic estimate of the ultimate resistance, but it requires a check of the ductility and rotation capacity of the components to ensure that the assumed redistribution can actually develop. For the present connection, the plate is relatively thick 15 mm and the bolts are of class 8.8, so that both components possess moderate ductility; the plastic redistribution is therefore likely to be partially mobilised, but a full plastic design should be verified by a component-based calculation.
The overall conclusion of Sections 3 to 5 is that the force in the outermost fastener of an eccentrically loaded out-of-plane bolt group is sensitive to the kinematic assumption, to the plate flexibility and prying action, and to the degree of plastic redistribution. The centroidal elastic formula provides a convenient but unreliable estimate, and a rigorous design should combine a shifted-axis elastic check with a component-based plastic check according to EN 1993-1-8.
6. Conclusion
6.1 Summary of findings
The present article has examined the force distribution in an eccentrically loaded out-of-plane bolt group, using a representative base-plate connection with six M20 bolts of class 8.8 arranged in three rows at y=50, 200, and 350 mm, and loaded by a 45 kN force applied at the upper edge of a 400 mm high plate. The eccentricity of the load with respect to the bolt group centroid was 200 mm, and the resulting moment about the centroid was 9000 kN⋅mm.
Three elastic kinematic assumptions were compared. Rotation about the bolt group centroid gave a top-bolt force of 22.5 kN but predicted a compressive force of −7.5 kN in the bottom row. Rotation about the bottom row gave 28.5 kN, and rotation about the bottom compression edge gave 26.59 kN; both of these distributions were entirely tensile but violated global equilibrium. A unique equilibrium-consistent elastic rigid-plate solution was found to place the centre of rotation at y=125 mm, again implying compression in the bottom row, and was therefore also physically inadmissible.
The analysis of plate flexibility and prying action showed that the actual force in the outermost fastener is higher than the centroidal prediction, because contact at the bottom edge introduces a prying reaction, and because the flexibility of the plate between the applied load and the top row concentrates the transmitted force in the immediate vicinity of the top bolts. The plastic analysis, based on the component method of EN 1993-1-8, showed that the ultimate resistance is governed by the relative capacities of the plate at the bottom edge and of the top-row bolts, and that plastic redistribution may raise the ultimate capacity above the elastic limit, provided that sufficient ductility is available.
6.2 Engineering takeaways
Four conclusions of direct engineering relevance follow from the analysis.
The centroidal formula is not applicable to out-of-plane eccentric loading without qualification. The formula Fi=F/n+M yi/∑yi2 presupposes that the connection can develop both tensile and compressive forces in the fasteners, and that the plate remains in contact with the support over the whole interface. Neither condition is satisfied by a real bolted connection, in which the fasteners transmit tension only and the contact is one-sided. For the geometry considered here, the formula yields a compressive force in the bottom row, which is physically impossible; the resulting top-bolt force is therefore a lower bound rather than a design value. The formula remains acceptable for connections in which the eccentricity is small enough that all fasteners remain in tension and the contact is maintained over the full interface, but this condition must be verified explicitly in each case.
The choice of the centre of rotation has a first-order influence on the result. The three assumptions examined produced top-bolt forces differing by approximately 27 %, from 22.5 to 28.5 kN. This spread is not numerical noise; it reflects genuine uncertainty in the kinematic description of a connection whose behaviour is governed by contact. A design based on the centroidal assumption alone therefore carries an unquantified margin of unconservatism.
Prying action and plate flexibility act in the same direction as the shift of the centre of rotation. Both effects increase the force in the outermost fastener beyond the centroidal prediction. The shift of the centre of rotation may be regarded as the global manifestation of the contact that prying produces locally, and the two should not be treated as independent corrections. For the present connection, a top-bolt force of the order of 30 kN, approximately 30 % above the centroidal prediction, appears plausible, although a quantitative value requires a contact-nonlinear or component-based analysis.
Elastic and plastic design answer different questions and should not be confused. Elastic analysis provides the force distribution at serviceability levels and identifies the most heavily loaded fastener. Plastic analysis, in the framework of EN 1993-1-8, provides the resistance at the ultimate limit state, accounting for the redistribution permitted by ductile components. The two analyses are complementary rather than alternative: the elastic check establishes whether the connection remains elastic under service loads, while the plastic check establishes the ultimate resistance and the governing failure mode. The use of a plastic distribution without verification of ductility, or the use of an elastic distribution to determine the ultimate resistance, is not consistent with the assumptions on which either method is based.
6.3 Recommendations for design
On the basis of the preceding analysis, the following procedure is recommended for the design of eccentrically loaded out-of-plane bolt groups in which the load acts at a significant distance from the bolt group centroid.
The centroidal elastic formula may be used as an initial estimate, but it should be supplemented by a check that all fasteners remain in tension. If the formula predicts compression in any row, the centroidal assumption is inadmissible and a shifted-axis or contact-based analysis should be adopted.
A component-based check according to EN 1993-1-8 should be carried out to identify the governing component, comparing the T-stub resistance of the plate at the compression edge with the tensile resistance of the most heavily loaded bolts. For the present connection, the tensile resistance of a single M20 bolt of class 8.8 is 141.1 kN, whereas the elastic top-bolt forces are in the range 22.5 to 28.5 kN; the bolts are therefore unlikely to govern in the elastic range, and the plate in bending at the bottom edge should be examined as the probable governing component.
Where the connection is required to develop its full plastic resistance, the ductility of the governing components should be verified, and the rotation capacity required to mobilise the assumed redistribution should be confirmed. The plastic reserve should not be relied upon if the governing failure mode is brittle, for example plate punching or bolt shear in a connection without sufficient deformation capacity.
6.4 Concluding remarks
The analysis presented in this article has shown that the force in the most heavily loaded fastener of an eccentrically loaded out-of-plane bolt group is not a uniquely determined quantity within the framework of rigid-plate elastic theory. The centroidal formula, although widely used and algebraically simple, is based on assumptions that are violated by the one-sided contact and the finite flexibility of real connections. The recognition of this limitation is not a purely academic matter: for the geometry considered here, the centroidal prediction is unconservative by approximately 30 % with respect to the physically admissible estimates, and the deficiency grows with increasing eccentricity.
A rigorous treatment requires either an analysis that admits the one-sided contact explicitly, or a component-based plastic analysis that identifies the governing failure mode and verifies the ductility required for redistribution. Both approaches are consistent with the framework of EN 1993-1-8, and both lead to a more reliable assessment of the connection than the unqualified application of the centroidal formula. The principal engineering conclusion is therefore that the classical elastic formula should be regarded as a starting point for the analysis of eccentrically loaded out-of-plane bolt groups, and not as a substitute for a treatment that respects the actual force-transmission mechanisms of the connection.
Technical Note: Domain of Validity and Practical Constraints
TN.1 Scope of the preceding analysis
The analyses presented in Sections 3 to 5 were developed for a base plate bearing directly against a supporting member, so that contact between the plate and the support is possible and a compression zone may develop at the lower edge. This condition is not universal. In numerous practical configurations the plate is not in contact with the support over its height, and the force-transmission mechanism is fundamentally different. The present note delineates the domain of validity of the preceding conclusions and draws attention to four aspects that must be considered before those conclusions are applied in design.
TN.2 The plate separated from the support: the double-nut configuration
A common practical arrangement consists of the plate being clamped between two nuts on each fastener — a positioning nut on the support side and a tightening nut on the exposed side — with a gap remaining between the plate and the supporting member. In this configuration the plate is not in contact with the support, and no bearing reaction can develop at the plate edge.
The mechanical consequence is decisive. Because the plate bears against the positioning nut, the fastener is able to transmit force to the plate in both senses: tension through the tightening nut and compression through the positioning nut. The one-sided constraint that invalidated the centroidal model in Section 3.1 is therefore removed. The rigid-plate elastic solution is no longer required to be one-sided, and the unique equilibrium-consistent distribution is obtained directly from rotation about the centroid of the bolt group:
For the geometry of Section 2, this gives Ftop=+22.5 kN and Fbot=−7.5 kN. The negative value is now physically admissible, because it represents bearing of the plate against the positioning nut and not compression transmitted through the bolt shank. The bolt itself may remain in tension as a result of preload; the sign of the calculated force refers to the direction of the force transmitted between plate and fastener, not to the stress state of the shank. The force in the top bolt is genuinely 22.5 kN, and the warnings of Sections 3.4 and 6.2 concerning unconservatism do not apply to this configuration.
Two qualifications must nevertheless be recorded. First, the validity of the centroidal solution depends on the gap being maintained throughout the service life of the connection. If deformation of the plate or of the support closes the gap, contact is established and the behaviour reverts to that described in Sections 3 to 5; the centroidal solution then becomes unconservative again. Second, the double-nut arrangement transmits force through bearing on the nuts, and the plate must be verified for bearing and for local bending in the vicinity of the nuts, which is not covered by the bolt-group analysis.
TN.3 Plastic deformation and prying action must respect the functional role of the assembly
The plastic redistribution discussed in Section 5 and the prying action discussed in Section 4 are legitimate design concepts only to the extent that the deformations they imply are compatible with the function that the assembly is required to perform. A connection that develops its full plastic resistance by yielding of the plate at the compression edge has, by definition, undergone permanent deformation at that location. Such deformation may be acceptable in a connection whose sole function is to transmit static load, but it may be unacceptable where the assembly must also satisfy requirements of tightness, retention of preload, resistance to fatigue, protection against corrosion, or maintenance of alignment.
In particular, the yielding of the plate at the toe limits the prying force, as noted in Section 5.3, but it simultaneously reduces the contact pressure at the interface and may permit the plate to separate from the support. Where the connection is required to remain closed — for example where the interface provides a sealing function or where slip resistance depends on the normal force — the plastification of the toe is not a reserve to be exploited but a limit state to be avoided. Similarly, plastic elongation of the bolts reduces the preload, and the resulting loss of clamping force may be more detrimental to the performance of the assembly than the additional tensile force that the plastic redistribution was intended to accommodate.
The plastic and prying analyses must therefore be supplemented by a verification that the deformation associated with the assumed mechanism does not compromise the functional role of the assembly. The resistance calculated by the component method is a resistance of the joint as a load-transmitting device; it is not, in itself, evidence that the assembly continues to perform its intended function.
TN.4 Applied moment at the centroid
In practical design the loading is frequently specified not as an eccentric force but as a moment applied at the centroid of the bolt group, the force resultant being zero. The analysis presented in Sections 3 to 6 remains valid in this case, and in one respect it is simplified. Since a couple is a free vector, the moment about any axis parallel to the applied moment is equal to the applied moment itself. The distinction between the three centres of rotation examined in Section 3 therefore disappears from the moment term, and the direct term vanishes because F=0. The distribution reduces to
which is antisymmetric about the centroid and sums to zero, in agreement with the condition of zero resultant force. The centroidal axis is the unique equilibrium-consistent centre of rotation for a symmetric bolt group under a pure moment, and the formula is exact within the rigid-plate idealisation.
The admissibility condition identified in Section 3.1 nevertheless persists. If the connection is in contact with the support, the compressive forces predicted in the rows on the compression side of the centroid can be transmitted only through contact, and if the moment is sufficiently large the plate will separate from the support over part of the interface. In that case the contact nonlinearity described in Section 4 governs, and the pure-moment formula ceases to be applicable without modification. Conversely, in the double-nut configuration of TN.2, the formula applies without restriction. The form of the loading does not by itself resolve the question of admissibility; that question is determined by the boundary conditions at the interface.
TN.5 The limits of standardised verification and the role of engineering judgement
The formulae of EN 1993-1-8 are resistance functions for individual components. They presuppose that the designer has selected a force distribution, has verified that the selected distribution is admissible for the connection considered, and has confirmed that the ductility required for any assumed redistribution is available. These presuppositions are not, and cannot be, verified by the standard itself, nor by software that implements the standard.
In current practice, the time available for the analysis of connections is frequently insufficient for the detailed consideration set out in Sections 3 to 5. Computational tools that apply the standard formulae automatically tend to obscure the assumptions on which those formulae rest: the choice between an elastic and a plastic distribution, the treatment of prying action, and the question of whether contact between the plate and the support is possible are either fixed by default settings or omitted altogether. The engineer is thereby placed in a position in which a numerical result is obtained without an assessment of whether the idealisation underlying it corresponds to the physical reality of the connection.
The consequence is that the judgement of whether the connection continues to perform its function during service life is displaced from the calculation to the interpretation of the calculation. This judgement cannot be automated. It requires an explicit decision on the kinematic model, an explicit check of admissibility, and an explicit consideration of the deformation and contact conditions over the service life of the assembly. The recommendation of Section 6.3 that the centroidal formula be supplemented by an admissibility check and by a component-based verification is therefore not merely a refinement of the calculation; it is a requirement for the result to be meaningful.
TN.6 Closing remark
The conclusions of Sections 3 to 6 are valid for a plate in contact with its support. They cease to apply, and the centroidal formula becomes exact, when the plate is separated from the support and clamped between nuts. Between these two limiting configurations lies the majority of practical connections, in which the degree of contact is uncertain and may change during the service life of the assembly. In that intermediate regime, no formula can substitute for an explicit statement of the assumed force-transmission mechanism and for an assessment of whether that mechanism is consistent with the function the connection is required to perform.