Local Buckling of Thin-Walled Sections

← All engineering notes

Slender compression elements where the effective width governs the resistance, and where the cross-section class decides whether a plastic or an elastic verification applies

1. Introduction

1.1 Practical context

Thin-walled steel sections are encountered in a broad class of structural and mechanical applications in which the ratio between the wall thickness and the characteristic width of the compressed plate is small: cold-formed profiles for purlins and cladding rails, hollow sections for columns and bracing members, box girders, and the slender plates of welded sections. In Romanian design practice these members are routinely verified according to the provisions of SR EN 1993-1-1 and SR EN 1993-1-5, which transpose the Eurocode framework for the classification of cross-sections and for the resistance of slender compression elements based on the effective width.

The problem addressed in this article is not one of arithmetic but of scope. The design office typically receives a profile, a design compressive force, and a set of partial factors; the cross-section is classified into one of the four classes, the effective properties are computed where required, and the compressive resistance is compared with the design force. The result is a utilisation ratio that appears to close the verification. The difficulty arises because the resistance obtained in this manner is the resistance of an isolated cross-section subjected to a uniformly distributed compressive stress applied at the centroid. In reality the compressive force is introduced through a connection — a bolted end plate, a gusset, a welded bracket, a bearing plate — and the manner in which the force is introduced governs whether the member behaves as verified or as a mechanism not represented in the calculation.

1.2 Conventional verification

In the conventional procedure the engineer proceeds in a fixed sequence. The cross-section is classified according to the width-to-thickness ratios of its compressed plate elements, as prescribed in SR EN 1993-1-1, Table 5.2. For slender elements (Class 4) the effective width is calculated according to SR EN 1993-1-5, §4.4, and the effective geometric properties are used to compute the compressive resistance:

Nc,Rd=AefffyγM0

in which Aeff is the effective area of the cross-section, fy is the yield strength, and γM0 is the partial factor for resistance of cross-sections. For Class 1 to 3 sections, Aeff is replaced by the gross area A. The utilisation ratio is then

η=NEdNc,Rd

where NE d is the design compressive force. This verification is correct in itself: it answers a well-posed question — namely, whether the isolated cross-section, subjected to a uniform compressive stress, can carry the design force without local buckling of its plate elements or without yielding. The deficiency lies not in the arithmetic but in the scope: the verification does not represent the mechanism by which the force is actually introduced into the member.

1.3 Limit of the conventional verification

Slender compression elements are sensitive to the manner of application of the compressive force. When the force is introduced through a connection that is not concentric, not uniformly distributed, or not aligned with the centroidal axis of the cross-section, the stress distribution over the cross-section becomes non-uniform. This non-uniformity is invisible to the global verification, because the global verification substitutes the real stress distribution with a uniform one, and it substitutes the real boundary conditions of the plate elements with the idealised simply-supported conditions of the effective-width model.

The consequence is that a member which satisfies the global verification may nevertheless fail by a local buckling mechanism induced by the connection. The mechanism is not represented in the conventional calculation because the conventional calculation does not include the connection in its domain. The verification answers the question "can the section carry the force?"; it does not answer the question "does the connection introduce the force in a manner consistent with the assumptions under which the resistance was calculated?".

1.4 Objective of the article

The objective of this article is to demonstrate quantitatively the difference in scope between the two verifications. It will be shown, by step-by-step calculation on a defined configuration, that:

the conventional verification yields a utilisation ratio below unity and is therefore correct in itself;

the governing mechanism — local buckling of a plate element induced by the non-uniform introduction of the compressive force at the connection — is not represented by the conventional verification;

the real stress distribution is non-uniform and produces an equivalent von Mises stress that the global verification does not detect;

the load case that produces failure is not included in the design brief;

the weakest component is not the one with the smallest cross-section, but the one with the most severe mechanism;

the resistance of the assembly is the resistance of the component governed by the most severe mechanism.

The demonstration is carried out on the configuration defined in Section 2, for which the conventional verification is performed in Section 3 and the mechanical verification in Section 4. Section 5 identifies the load case absent from the design brief. Section 6 discusses the plastic distribution and the failure mode. Section 7 states the conclusions and the recommendations for design.

2. Problem Statement & Geometry

2.1 Reference configuration

The demonstration is carried out on a single, fully defined reference configuration. All subsequent calculations — the conventional verification in Section 3 and the mechanical verification in Section 4 — refer to this configuration and to no other. The configuration is chosen because it is representative of a large class of thin-walled compression members in Romanian practice and because it exhibits, in a transparent and calculable manner, the difference in scope between the two verifications.

The member is a cold-formed square hollow section (SHS) used as a compression diagonal in a braced steel frame. The member is pin-ended at both nodes and is loaded axially through a slotted gusset connection at each end. The connection is the component through which the compressive force is introduced into the section, and it is the component that the conventional verification does not model.

2.2 Geometry

The cross-section is a cold-formed SHS 200 × 200 × 3.0, with the following nominal dimensions:

b=h=200.0 mm,t=3.0 mm

The external corner radius of the cold-formed section is taken as ro=1.5t=4.5 mm, and the internal corner radius as ri=ro−t=1.5 mm. The flat width of each wall, according to the simplification c=b−3t permitted for cold-formed hollow sections, is

c=200.0−3×3.0=191.0 mm

and the width-to-thickness ratio of the compressed wall is

ct=191.03.0=63.7

The geometric properties of the gross cross-section are:

A=2t(b+h−2t)−(4−π)(ro2−ri2)=2348.6 mm2
I=1.49×107 mm4,Wel=1.49×105 mm3,i=79.6 mm

The member length between pinned nodes is

L=3000.0 mm

and the buckling length about both principal axes is taken equal to the system length, Lcr=L=3000.0 mm.

The connection at each end consists of a slotted gusset plate of thickness tg=10.0 mm, inserted longitudinally into a slot cut in two opposite walls of the SHS. The slot length is

lw=300.0 mm

and the gusset is welded to each of the two slotted walls by two fillet welds of leg size z=3.0 mm (limited by the thickness of the SHS wall, which is the thinner connected part), giving a weld throat of

a=0.7×3.0=2.1 mm

The gusset is connected to the main frame by two preloaded bolts M20 class 10.9, with the following characteristics: tensile stress area As=245.0 mm2, ultimate tensile strength fub=1000.0 MPa, and preload

Fp,c=0.7fubAs=0.7×1000.0×245.0=171.5 kN

2.3 Materials and partial factors

The section is of steel grade S275, with the following nominal properties:

fy=275.0 MPa,fu=430.0 MPa,E=210000.0 MPa,ν=0.3

The partial factors are those of the Romanian National Annex to SR EN 1993:

γM0=1.0,γM1=1.0,γM2=1.25

The material factor for the evaluation of the plate slenderness is

ε=235fy=235275=0.924

2.4 Cross-section classification

For an internal compression element, the Class 3 limit is 42ε=38.8. Since

ct=63.7>42ε=38.8

the cross-section is Class 4. The resistance of the compressed wall is therefore governed by the effective width, and the verification is elastic: no plastic redistribution of stress is permitted, and the effective geometric properties must be used in place of the gross properties. This classification is the point at which the subtitle of the article becomes operative: the cross-section class decides whether a plastic or an elastic verification applies, and for this configuration the elastic (effective width) verification applies.

2.5 Loading

The design compressive force in the member, obtained from the permanent and variable actions of the design brief, is

NEd=1.35Gk+1.5Qk=1.35×160.0+1.5×100.0=366.0 kN

The service force is Nser=Gk+Qk=260.0 kN. The installation force, corresponding to the preload of the two M20 bolts, is 2Fp, c=343.0 kN, which is of the same order as the design force and is therefore not negligible in the local stress state at the connection. The range of variation of the force under repeated loading is taken as ΔN=120.0 kN.

In addition to the primary load case, the member is subjected to a compatibility force arising from the thermal expansion of the main frame. For a temperature variation ΔT=25.0 K and a coefficient of thermal expansion α=1.2×10−5 K−1, the free thermal strain is

εth=αΔT=1.2×10−5×25.0=3.0×10−4

and the corresponding free thermal force is

Nth=εthEA=3.0×10−4×210000.0×2348.6=148.0 kN

For a frame restraint of 50 %, the effective thermal force introduced into the bracing is Nth, eff=74.0 kN, and the total force becomes

NEd,total=366.0+74.0=440.0 kN

This load case is not included in the design brief, and its consequences are examined in Section 5.

2.6 Secondary parameters

The following secondary parameters are retained because they affect the local stress state at the connection and therefore the mechanism examined in Section 4:

Friction coefficient at the bolted interface: μ=0.3 (surface class A, untreated).

Lubrication: none; the bolts are tightened dry, with a torque coefficient K=0.20.

Tolerance on hole clearance: standard clearance for M20, 2.0 mm.

Wear and relaxation: preload loss of 10% over the design life, giving an effective preload Fp, c, eff=154.4 kN per bolt.

The slip resistance of the bolted connection is

Fs,Rd=ksnμFp,cγM3=1.0×2×0.3×171.51.25=82.3 kN

Since the design force per bolt, NE d/2=183.0 kN, exceeds Fs, R d=82.3 kN, the connection operates in bearing rather than in slip-resistant mode. This is a secondary consequence of the design brief and is not pursued further here; it is mentioned because it confirms that the load path at the connection is not the idealised one assumed in the conventional verification.

2.7 The two verifications to be compared

Two verifications are compared in the following sections.

Verification A — the conventional verification ("the structural engineer"). The cross-section is classified, the effective width is computed for a uniformly compressed internal element, the effective area is obtained, and the compressive resistance is calculated as

Nc,Rd=AefffyγM0

The utilisation ratio is ηA=NE d/Nc, R d. This verification answers the question: can the isolated cross-section, subjected to a uniform compressive stress, carry the design force without local buckling of its plate elements?

Verification B — the mechanical verification (the governing mechanism). The compressive force is introduced into the section through the slotted gusset, and the wall of the SHS is loaded locally along the weld lines. The local stress at the weld line is calculated, the local buckling stress of the wall is calculated, and the load at which local buckling initiates is compared with the design force. The utilisation ratio is ηB=NE d/Ncr, local. This verification answers the question: does the connection introduce the force in a manner consistent with the uniform-stress assumption under which the resistance in Verification A was calculated?

The two verifications are not alternative methods for the same question. They answer different questions, and the article demonstrates that the answer to the second question is not contained in the answer to the first.

3. Conventional verification — “the structural engineer”

3.1 The standard formula and the step-by-step calculation

The conventional verification of a thin-walled compression member proceeds in the sequence prescribed by SR EN 1993-1-1 and SR EN 1993-1-5. The sequence is reproduced below in full, on the configuration of Section 2, so that each intermediate quantity can be verified independently.

3.1.1 Cross-section classification

The compressed walls of the SHS are internal plate elements in uniform compression. For an internal compression element the Class 3 limit, according to SR EN 1993-1-1, Table 5.2 (sheet 1 of 3), is

(ct)lim,3=42ε=42×0.924=38.8

The actual width-to-thickness ratio, calculated in Section 2.2, is c/t=63.7. Since

ct=63.7>42ε=38.8

the cross-section is Class 4. The consequence is twofold and is stated explicitly because it governs the entire subsequent calculation: the resistance is computed with the effective geometric properties, and no plastic redistribution of stress is permitted. The verification is elastic.

3.1.2 Effective width

The effective width of the compressed internal element is calculated according to SR EN 1993-1-5, §4.4. The plate slenderness is

λ¯p=c/t28.4εkσ

where kσ is the buckling coefficient of the plate. For an internal element in uniform compression (ψ=1.0), kσ=4.0, and therefore

λ¯p=63.728.4×0.924×4.0=63.752.48=1.214

The reduction factor is calculated according to SR EN 1993-1-5, §4.4(2). The threshold for the reduction is

λ¯p=0.673+0.055(3+ψ)λ¯=0.673+0.055×4.01.214=0.673+0.181=0.854

Since λ̄p=1.214 > λ̄p, 0=0.854, the reduction factor is

ρ=λ¯p−0.055(3+ψ)λ¯p2=1.214−0.2201.2142=0.9941.474=0.674

The effective width of the compressed wall is therefore

beff=ρc=0.674×191.0=128.8 mm

and it is distributed symmetrically, be1=be2=beff/2=64.4 mm at each edge, with a central ineffective zone of

c−beff=191.0−128.8=62.2 mm

The ineffective zone is the portion of the wall that buckles locally and is therefore removed from the resisting section.

3.1.3 Effective area

Each of the four walls of the SHS loses the central ineffective strip of width 62.2 mm and thickness 3.0 mm. The total ineffective area is

ΔA=4×62.2×3.0=746.4 mm2

and the effective area, obtained from the gross area A=2348.6 mm2 calculated in Section 2.2, is

Aeff=A−ΔA=2348.6−746.4=1602.2 mm2

The ratio Aeff/A=1602.2/2348.6=0.682 confirms that approximately one third of the gross area is ineffective under uniform compression — a quantitative measure of how slender the section is.

3.1.4 Compressive resistance of the cross-section

The design compressive resistance of the cross-section is calculated according to SR EN 1993-1-1, §6.2.4:

Nc,Rd=AefffyγM0=1602.2×275.01.0=440605 N=440.6 kN

3.1.5 Flexural buckling resistance

Because the member is a compression member of finite length, the engineer does not stop at the cross-section resistance. The flexural buckling resistance is calculated according to SR EN 1993-1-1, §6.3.1. The relative slenderness about the weak axis is

λ¯=Lcriλ1,λ1=πEfy=π210000.0275.0=86.8
λ¯3000.079.6×86.8=3000.06909.3=0.434

For a cold-formed hollow section, buckling curve c applies (SR EN 1993-1-1, Table 6.2), with imperfection factor α=0.49. The auxiliary parameter is

Φ=0.5[1+α(λ¯0.2)+λ¯2]=0.5[1+0.49×0.234+0.4342]=0.5×1.3027=0.651

and the reduction factor is

χ=1Φ+Φ2−λ¯2=10.651+0.4238−0.1884=10.651+0.4852=0.880

The flexural buckling resistance is therefore

Nb,Rd=χAefffyγM1=0.880×1602.2×275.01.0=387733 N=387.7 kN

3.2 Degree of utilisation at the service and design loads

The utilisation ratios at the service load Nser=260.0 kN and at the design load NE d=366.0 kN are:

ηc,ser=260.0440.6=0.590,ηc,Ed=366.0440.6=0.831

for the cross-section resistance, and

ηb,ser=260.0387.7=0.671,ηb,Ed=366.0387.7=0.944

for the flexural buckling resistance. Both verifications are satisfied at the design load. The governing conventional check is flexural buckling, with ηb, E d=0.944. The margin is small — 5.6% — which is itself an observation of practical importance: the member is designed close to its conventional limit, so any effect not represented in the conventional verification has little reserve in which to be absorbed.

3.3 What the verification covers

The conventional verification, as executed in §3.1, covers the following failure modes and validity conditions:

Local buckling of the compressed plate elements under a uniformly distributed compressive stress, represented by the effective width reduction of §3.1.2. The model assumes the plate is simply supported along its longitudinal edges and free to buckle in the central ineffective zone.

Yielding of the effective cross-section under a uniformly distributed compressive stress, represented by the resistance of §3.1.4.

Flexural buckling of the member as an isolated bar about the weak axis, represented by the reduction factor χ of §3.1.5. The model assumes the member is pinned at both ends, loaded concentrically, and free of end moments.

The validity of the material model — elastic-perfectly plastic, with fy=275.0 MPa and E=210000.0 MPa, valid up to the yield plateau.

The verification is internally consistent and correct within these assumptions. The arithmetic of §3.1 has been reproduced in full so that it can be checked independently, and it is correct.

3.4 What the verification does not cover

The conventional verification, as executed in §3.1, does not cover the following mechanisms, all of which are outside its scope by construction:

The manner of introduction of the compressive force. The verification assumes the force is applied at the centroid, uniformly distributed over the cross-section. The real force is introduced through a slotted gusset welded to two opposite walls, and the local stress state at the weld line is not uniform.

The non-uniform distribution of stress over the cross-section resulting from the connection. The verification replaces the real stress distribution with a uniform one; the difference between the two is not represented.

Local buckling of the wall induced by the connection, as distinct from local buckling of the wall under uniform compression. The effective-width model of §3.1.2 is calibrated for the latter, not the former.

The compatibility forces arising from thermal expansion, foundation settlement, or loss of preload. These are not part of the design brief and are not included in NE d.

The interaction between the local stress at the connection and the global compressive stress in the member. The two are calculated separately and are not superimposed in the conventional verification.

The bearing and slip behaviour of the bolted connection, and the secondary bending it introduces into the gusset and into the slotted walls.

The fatigue and wear degradation of the connection under repeated loading, which alters the stress distribution over the design life.

This list is not a criticism of the verification. It is a statement of its domain of validity. The verification answers a well-posed question — can the isolated cross-section, subjected to a uniform compressive stress, carry the design force without local buckling of its plate elements and without flexural buckling of the bar? — and it answers it correctly. The question it does not answer is whether the connection introduces the force in a manner consistent with the assumptions under which the answer was obtained.

3.5 The verification is correct in itself; the deficiency is of scope

It must be emphasised, because the argument of this article depends on it, that the conventional verification is not wrong. The arithmetic of §3.1 is correct; the partial factors are correctly applied; the classification is correct; the effective width is correctly calculated; the buckling curve is correctly selected. An error in any of these would be a different problem, and it is not the problem addressed here.

The deficiency is one of scope. The verification substitutes a uniform stress distribution for the real one, a concentric load for the real one, and an isolated bar for the real member-with-connection. Each substitution is legitimate within the domain of the verification; none of them is legitimate outside it. The question posed in Section 1.4 — whether the connection introduces the force in a manner consistent with the assumptions of the verification — is not answered by the verification, and cannot be answered by it, because the connection is not in its domain.

The consequence is quantitative and is demonstrated in Section 4: the mechanism by which the member actually fails is not the mechanism verified in §3.1, and the resistance associated with that mechanism is not the resistance calculated in §3.1. The two resistances answer different questions. The remainder of the article is devoted to calculating the second resistance and to showing that it, and not the first, governs the design.

A final observation is recorded here and developed in Section 5. The conventional utilisation at the design load is ηb, E d=0.944, which leaves a margin of 5.6%. If the force were to increase — as it does in the load case examined in Section 5, where a thermal compatibility force is superimposed on the design force — the utilisation would approach and exceed unity. The conventional verification would then fail, but it would fail for a reason that is not the reason for which the member actually fails. The distinction is central to the argument of this article.

4. Mechanical verification — the governing mechanism

4.1 The governing mechanism: local buckling of the wall induced by the connection

4.1.1 Model and assumptions

The conventional verification of Section 3 treats the compressed wall as a plate simply supported along its two longitudinal edges and subjected to a uniformly distributed compressive stress. The mechanical verification treats the same wall as a plate simply supported along the same two longitudinal edges, but subjected to a line load applied at its centre line over the length of the welded slot. The difference between the two models is not the plate — it is the same plate — but the load introduction, and it is the load introduction that governs the resistance.

The following assumptions are adopted for the mechanical model:

The compressive force is introduced into the section exclusively through the two slotted walls. Each slotted wall receives one half of the design force:

Nw=NEd2=366.02=183.0 kN

The force is transmitted from the gusset to the wall through the two fillet welds, which run longitudinally along the slot edges over the length lw=300.0 mm. The line load intensity per wall is

q=Nwlw=183.0300.0=0.610 kN/mm=610.0 N/mm

The wall is simply supported along its two longitudinal edges by the perpendicular walls. The support is not rigid — the perpendicular walls themselves have a finite stiffness — but for the purpose of the local buckling check the simply-supported idealisation is retained, as in the conventional verification, so that the two verifications differ only in the load introduction and not in the boundary conditions.

The load spreads from the weld line into the wall. The width over which the load is effectively distributed is taken, conservatively, as

be=lw2=300.02=150.0 mm

This width represents the central region of the wall in which the longitudinal stress is high enough to govern the local buckling. It is smaller than the full flat width c=191.0 mm, and this reduction is the quantitative expression of the fact that the load is concentrated at the centre rather than distributed over the full width.

4.1.2 Plate slenderness of the loaded region

The plate slenderness of the loaded region is calculated with the same expression as in Section 3.1.2, but with the effective width be in place of the flat width c, and with the buckling coefficient kσ=4.0 for an internal element:

λ¯p,local=be/t28.4εkσ=150.0/3.028.4×0.924×4.0=50.052.48=0.953

4.1.3 Reduction factor and effective width of the loaded region

Since λ̄p, local=0.953 > 0.673, the reduction factor is calculated according to SR EN 1993-1-5, §4.4(2):

ρlocal=λ¯p,local−0.055(3+ψ)λ¯p,local=0.953−0.055×4.00.9532=0.953−0.2200.908=0.807

The effective width of the loaded region is therefore

beff,local=ρlocalbe=0.807×150.0=121.1 mm

and the ineffective width of the loaded region is

be−beff,local=150.0−121.1=28.9 mm

4.1.4 Local buckling resistance of one wall

The effective area of the loaded region of one wall is

Aeff,local=beff,localt=121.1×3.0=363.3 mm2

and the local buckling resistance of one wall is

Ncr,local=Aeff,localfy=363.3×275.0=99908 N=99.9 kN

4.1.5 Local buckling resistance of the member at the connection

The force is introduced through two slotted walls, each of which resists Ncr, local. The local buckling resistance of the member at the connection is therefore

Ncr,local,total=2Ncr,local=2×99.9=199.8 kN

4.1.6 Comparison with the conventional resistance

The comparison between the conventional resistance of Section 3 and the mechanical resistance of §4.1.5 is the central quantitative result of this article:

Nb, R d=387.7 kN (conventional, Section 3.1.5)   |   Ncr, local, total=199.8 kN (mechanical, §4.1.5)

The ratio between the two is

Nb,RdNcr,local,total=387.7199.8=1.94

The conventional verification overestimates the resistance associated with the actual mechanism by a factor of 1.94. The utilisation ratios are:

ηb, E d=366.0/387.7=0.944 (conventional)   |   ηlocal, E d=366.0/199.8=1.83 (mechanical)

The conventional verification reports a safe member with a margin of 5.6%. The mechanical verification reports a member whose connection region is utilised at 183% of its local buckling resistance. The two verifications answer different questions, and the answer to the second question is not contained in the answer to the first. This is the quantitative demonstration of argumentative thread 2: the governing mechanism is not represented by the conventional verification.

4.2 Non-uniform distribution of stress

4.2.1 Model of the real distribution

The conventional verification substitutes the real stress distribution over the wall with a uniform distribution, σ=NE d/Aeff. The mechanical verification retains the real distribution, which is non-uniform because the force is introduced along the centre line of the wall and must spread to the supported edges.

The average longitudinal stress over the full flat width of one wall, at the connection, is

σavg=Nwct=183000191.0×3.0=183000573.0=319.4 MPa

This average already exceeds the yield strength fy=275.0 MPa by 16.1%. The distribution about this average is not uniform: the stress is highest at the centre line (where the load is applied) and lowest at the supported edges. A linear distribution is adopted as a first approximation, with the peak at the centre line and the edge stress equal to one half of the peak:

σedge=0.5σpeak

The average of a linear distribution between σedge and σpeak is (σedge+σpeak)/2, so

0.5σpeak+σpeak2=319.4 MPa⇒0.75σpeak=319.4 MPa⇒σpeak=425.9 MPa

and therefore

σedge=0.5×425.9=212.9 MPa

4.2.2 Consequence of the non-uniformity

The peak stress at the centre line, σpeak=425.9 MPa, exceeds the yield strength by 54.9% and approaches the ultimate strength fu=430.0 MPa. The edge stress, σedge=212.9 MPa, remains below yield. The wall is therefore partially yielded at the connection: the central region is at or near the ultimate stress, while the edges are still elastic.

The ratio between the peak stress and the uniform stress assumed in the conventional verification is

σpeakσconv=425.9NEd/Aeff=425.9366000/1602.2=425.9228.4=1.86

The real peak stress is 1.86 times the uniform stress assumed in the conventional verification. This is the quantitative expression of argumentative thread 3: the real stress distribution is non-uniform and invisible to the global verification. The conventional verification would report a stress of 228.4 MPa against a yield strength of 275.0 MPa, with a stress utilisation of 0.831. The real peak stress is 425.9 MPa, with a stress utilisation against yield of 1.55 and against ultimate of 0.990. The difference between 0.831 and 0.990 is the difference between a safe member and a member at the point of rupture, and it is produced entirely by the non-uniformity of the load introduction.

4.3 Combined stress state

4.3.1 Stress components at the centre line

The wall at the centre line, in the immediate vicinity of the weld, is not in a state of uniaxial stress. Three stress components are present:

Longitudinal stress. This is the peak stress calculated in §4.2.1:

σx=σpeak=425.9 MPa

Transverse stress. The longitudinal stress produces a transverse strain through the Poisson effect, εy=−νεx. The transverse stress that develops depends on the restraint provided by the perpendicular walls and by the weld. A conservative estimate, corresponding to full restraint of the Poisson expansion, is

σy=νσx=0.3×425.9=127.8 MPa

Shear stress. The spreading of the load from the centre line towards the supported edges produces a shear stress in the plane of the wall. A conservative estimate, corresponding to a spread angle of approximately 45∘, is

τxy=0.2σx=0.2×425.9=85.2 MPa

4.3.2 Von Mises equivalent stress

The von Mises equivalent stress for a plane stress state is

σvm=σx2−σxσy+σy2+3τxy2

Substituting the components:

σvm=√(425.92−425.9×127.8+127.82+3×85.22)   |   σvm=√(181390.8−54430.0+16332.8+21777.1)=√(165070.7)=406.3 MPa

4.3.3 Consequence of the combined stress state

The von Mises equivalent stress at the centre line is σvm=406.3 MPa. Its ratios to the material strengths are

σvmfy=406.3275.0=1.48,σvmfu=406.3430.0=0.945

The equivalent stress exceeds the yield strength by 48% and reaches 94.5% of the ultimate strength. The conventional verification, which computes a uniaxial stress of 228.4 MPa and compares it with fy=275.0 MPa, does not detect this state: the combined stress state is a consequence of the load introduction, and the load introduction is outside the domain of the conventional verification. The von Mises stress at the connection is 1.78 times the uniform stress of the conventional verification:

σvmσconv=406.3228.4=1.78

This is the quantitative expression of the fact that the conventional verification does not merely underestimate the stress — it computes a different stress in a different stress state, and the difference is not a matter of a factor applied to the same quantity but a matter of a different physical quantity altogether.

4.4 Strength hierarchy between components

4.4.1 Capacities of the components

The connection comprises several components, each with its own resistance and its own mechanism. The capacities calculated in Sections 2 to 4 are collected below, together with the additional capacities of the welds and of the bolts calculated in Section 2.6 and in §4.1.

Slip resistance of the bolted connection (two bolts, §2.6):

Fs,Rd,total=2×82.3=164.6 kN

Bearing resistance of the bolted connection (two bolts, Fb, R d=86.0 kN per bolt):

Fb,Rd,total=2×86.0=172.0 kN

Shear resistance of the bolted connection (two bolts, Fv, R d=98.0 kN per bolt):

Fv,Rd,total=2×98.0=196.0 kN

Local buckling resistance of the member at the connection (§4.1.5):

Ncr,local,total=199.8 kN

Flexural buckling resistance of the member (§3.1.5):

Nb,Rd=387.7 kN

Cross-section resistance (§3.1.4):

Nc,Rd=440.6 kN

Weld resistance (per wall, Fw, R d=fvw, dalw×2, with fvw, d=fu/(√(3)βwγM2)=430.0/(1.732×0.9×1.25)=220.7 MPa):

Fw, R d=220.7×2.1×300.0×2=278082 N=278.1 kN per wall   |   Fw, R d, total=2×278.1=556.2 kN

4.4.2 Hierarchy and identification of the governing component

The capacities are arranged in ascending order:

ComponentMechanismCapacity (kN)Utilisation NE d/R
Bolted connection, slipFriction164.62.22
Bolted connection, bearingBearing172.02.13
Bolted connection, shearShear196.01.87
SHS wall at connectionLocal buckling199.81.83
Member, flexural bucklingGlobal buckling387.70.94
Cross-sectionYielding / local buckling440.60.83
WeldShear556.20.66

The hierarchy exhibits three features that are central to the argument of this article.

First, the weakest component is not the one with the smallest cross-section. The weld has the smallest throat of any component — a=2.1 mm — and yet it is the strongest, with a capacity of 556.2 kN. The cross-section has the largest area — 2348.6 mm2 — and yet it is not the strongest relative to its mechanism. The component that governs is the SHS wall at the connection, whose cross-section is 191.0×3.0=573.0 mm2 per wall, larger than the weld throat but smaller than the gross section. The ranking of capacities does not follow the ranking of cross-sectional areas; it follows the ranking of mechanisms. This is the quantitative expression of argumentative thread 5: the weakest component is not the one with the smallest cross-section.

Second, the conventional verification and the mechanical verification identify different governing components. The conventional verification identifies flexural buckling as the governing check, with ηb, E d=0.944. The mechanical verification identifies local buckling of the wall at the connection as the governing mechanism, with ηlocal, E d=1.83. The two verifications do not merely disagree on the value of the utilisation; they disagree on which component governs. The conventional verification places the governing mechanism in the member, away from the connection; the mechanical verification places it at the connection, in the wall. The connection is not a detail of the member — it is the component that governs the member.

Third, the resistance of the assembly is the resistance of the component with the most severe mechanism. The assembly — member plus connection — cannot resist more than its weakest component. The bolted connection resists 164.6 kN in slip and 172.0 kN in bearing; the wall resists 199.8 kN in local buckling; the member resists 387.7 kN in flexural buckling. The resistance of the assembly is therefore 164.6 kN, governed by the slip of the bolted connection — not by the flexural buckling of the member. If the bolted connection is excluded from the comparison, because it is a separate design issue with its own treatment, the governing component of the member-and-weld assembly is the wall at the connection, with 199.8 kN. In either case, the resistance of the assembly is the resistance of the component with the most severe mechanism, and the most severe mechanism is at the connection. This is the quantitative expression of argumentative thread 6: the resistance of the assembly is the resistance of the component with the most severe mechanism.

4.4.3 The connection governs the member

The conclusion of Section 4 is stated in the form in which it will be carried into Section 5 and Section 6. The conventional verification of Section 3 is correct in itself: it answers the question whether the isolated cross-section, under a uniform compressive stress, can carry the design force. It answers that question affirmatively, with ηb, E d=0.944. But the question it answers is not the question that governs the design, because the force is not introduced uniformly and the cross-section is not isolated. The force is introduced through a connection, and the connection produces a local stress state whose peak is 1.86 times the uniform stress and whose von Mises equivalent is 1.78 times the uniform stress. The local buckling resistance at the connection is 199.8 kN, and the design force is 366.0 kN. The connection, not the member, governs, and the mechanism by which it governs — local buckling of the wall induced by the non-uniform introduction of the force — is not represented in the conventional verification.

5. The load case missing from the design brief

5.1 Origin of the missing load case

The design force of Section 2.5, NE d=366.0 kN, is obtained from the permanent and variable actions of the design brief. It is a force that the designer controls: it is specified by the brief, it is combined according to the rules of SR EN 1990, and it is applied to the member in the calculation as a known quantity. There exists, however, a second class of forces that the brief does not contain and that the designer does not control: compatibility forces arising from the restraint of imposed deformations. These forces are not actions in the sense of the applied load; they are the structural response to a deformation that the member is prevented from accommodating freely, and their magnitude is governed by the stiffness of the restraint rather than by the magnitude of the load.

The physical phenomena that produce compatibility forces in a braced steel frame are the following.

Thermal variation. The main frame and the bracing member are exposed to temperature variations that differ from the temperature at which the frame was erected. The free thermal strain is εth=αΔT, and if the frame restrains the bracing against free expansion, a thermal force develops that is proportional to the restraint stiffness. This is the phenomenon quantified in Section 2.5, and it is the one that is examined quantitatively in §5.3.

Foundation settlement. Differential settlement between the supports of the braced bay imposes a relative displacement on the bracing member. The force developed is proportional to the settlement and to the axial stiffness of the member, N=(E A/L)δ, and it is not controlled by any element of the connection. For the configuration of Section 2, the axial stiffness is E A/L=210000.0×2348.6/3000.0=164402 N/mm, so a differential settlement of δ=1.0 mm produces a force of 164.4 kN — comparable to the design force itself, from a displacement that is within the tolerance of any foundation.

Creep of adjacent concrete elements. Where the bracing is connected to a concrete core or to a concrete-filled column, the creep of the concrete under sustained load transfers force to the bracing over the design life. The force is not present at the time of erection and is not visible in the short-term load case; it develops over years and is proportional to the sustained load and to the creep coefficient.

Loss of preload in the bolted connection. The preload of Section 2.2, Fp, c=171.5 kN per bolt, is not constant over the design life. Relaxation of the bolt, embedding of the surfaces, and vibration produce a loss that is typically 10% to 20% of the initial preload. The consequence is not a change in the applied force but a change in the load path: the slip resistance of §2.6 decreases, the connection transitions from slip-resistant to bearing mode, and the local stress distribution at the weld changes. The force in the member is the same; the manner in which it is transmitted is not.

Construction tolerances. The member is fabricated with a length tolerance and is installed with an erection tolerance. A misfit between the fabricated length and the as-built distance between nodes produces a force at installation that is locked into the member and is not removed by the subsequent application of the design load. For a member of length 3000.0 mm fabricated with a tolerance of ±2.0 mm, the installation force is 164402×2.0=328.8 kN — again of the same order as the design force, and present from the moment of erection.

None of these forces is a load in the sense of the design brief. All of them are real, all of them are unavoidable, and all of them are additive to the design force.

5.2 Mechanics of the operation and absence of force control

The essential mechanical difference between the design force and the compatibility forces is the following. The design force is applied through the member and is limited by the actions that produce it: if the variable action is 100.0 kN, the force transmitted through the member cannot exceed the value obtained from the combination of the actions, because the actions themselves are bounded by the brief. The compatibility force, by contrast, is applied to the member by the restraint, and it is limited only by the stiffness of the restraint and by the strength of the member. There is no element in the load path that limits it.

This is the reason why the compatibility force is not controlled. In a hydraulically preloaded system, the force is controlled by a gauge and is limited by a relief valve. In a bolted connection, the preload is controlled by a torque wrench and is limited by the strength of the bolt. In a bracing member restrained by a frame, there is no force-limiting device: the member is connected to the frame at both ends, and the force that develops is whatever the compatibility of deformations requires. The only limit is the strength of the member and of its connection, and if that limit is reached, the member does not shed the force — it fails.

The consequence for the design is direct. The conventional verification of Section 3 is performed against a force that is known, bounded, and controlled. The compatibility force is neither known with precision, nor bounded by the brief, nor controlled by any device. It is a force whose magnitude is governed by a stiffness that the designer does not calculate and by a deformation that the designer does not specify. The verification of Section 3 is therefore performed against the wrong force, not because the force is calculated incorrectly, but because the force that governs is not the force that was calculated.

5.3 Dispersion and quantitative consequence

The thermal force of Section 2.5 is calculated for a single pair of values: ΔT=25.0 K and a restraint of 50%. Neither value is known with precision. The temperature variation in a Romanian climate ranges from −25.0 K to +35.0 K relative to the erection temperature, and the restraint provided by the frame depends on the stiffness of the columns and of the connections, which is itself uncertain. The force is therefore a random variable, not a deterministic quantity, and its dispersion must be quantified.

5.3.1 Dispersion of the thermal force

The free thermal force is

Nth=αΔTEA

For the range ΔT∈[−25.0,+35.0] K, with α=1.2×10−5 K−1, E=210000.0 MPa, and A=2348.6 mm2:

Nth=1.2×10−5×ΔT×210000.0×2348.6=5.92ΔT[ kN]
Nth∈[−148.0,+207.2] kN

The effective force transmitted to the bracing depends on the restraint coefficient kr∈[0, 1], which represents the fraction of the free thermal force that the frame actually transmits:

Nth,eff=krNth

For a restraint between 30% and 70%, the effective thermal force ranges from

Nth,eff,min=0.30×(−148.0)=−44.4 kN

to

Nth,eff,max=0.70×207.2=+145.0 kN

The total force in the member, obtained by superposition of the design force and the thermal force, ranges from

NEd,total,min=366.0−44.4=321.6 kN

to

NEd,total,max=366.0+145.0=511.0 kN

The upper bound, 511.0 kN, is 39.6% above the design force of 366.0 kN, and it is obtained from a temperature variation and a restraint that are both within the range of normal service conditions. The design force is not the maximum force; it is the median of a distribution whose upper tail exceeds it by a factor of 1.40.

5.3.2 Consequence for the conventional verification

The conventional verification of Section 3 is repeated at the upper bound of the total force:

ηb,max=NEd,total,maxNb,Rd=511.0387.7=1.32

At the upper bound of the thermal force, the conventional verification fails: the flexural buckling resistance of 387.7 kN is exceeded by 32%. The member that was reported safe at ηb, E d=0.944 is reported unsafe at the upper bound of the load case that the brief does not contain. The conventional verification does not fail because the arithmetic of Section 3 is wrong; it fails because the force to which the arithmetic is applied is not the force that the member actually experiences.

5.3.3 Consequence for the mechanical verification

The mechanical verification of Section 4 is repeated at the upper bound:

ηlocal,max=NEd,total,maxNcr,local,total=511.0199.8=2.56

and at the lower bound:

ηlocal,min=NEd,total,minNcr,local,total=321.6199.8=1.61

The local buckling resistance of the wall at the connection, 199.8 kN, is exceeded at both bounds of the load case. The member does not merely become unsafe at the upper bound; it is unsafe at the lower bound as well. The mechanism is not a marginal effect that appears only in extreme conditions — it is present throughout the range of the load case, and the design force of 366.0 kN is already 83% above the local buckling resistance, before any thermal force is added.

5.3.4 Consequence for the bolted connection

The slip resistance of the bolted connection, Fs, R d, total=164.6 kN (§2.6), is exceeded at the design force itself:

ηslip,Ed=366.0164.6=2.22

The connection is in bearing mode from the outset, and the bearing resistance, Fb, R d, total=172.0 kN, is also exceeded:

ηbearing,Ed=366.0172.0=2.13

The bolted connection is therefore the component with the most severe mechanism under the design force, and its severity increases with the addition of the compatibility force. The hierarchy of Section 4.4.2 is not altered by the compatibility force — the order of components is preserved — but the utilisation of every component increases, and the governing component, whether it is the bolted connection or the wall at the connection, is utilised at more than twice its resistance at the lower bound of the load case.

5.4 Why the case is classified outside the brief, and the consequence of the classification

5.4.1 The classification

The compatibility force is classified outside the design brief for a reason that is formal and, within its own logic, correct. In the framework of SR EN 1990, the thermal variation, the foundation settlement, and the construction tolerance are indirect actions: they are not applied loads but imposed deformations, and their treatment is governed by the rules for imposed deformations rather than by the rules for applied loads. The design brief of a braced frame typically specifies the applied loads — permanent, variable, wind, snow — and treats the imposed deformations as a separate serviceability check, often outside the ultimate limit state verification of the individual members.

The classification is reinforced by a practical argument that is frequently made in design offices: the bracing member is a secondary element, and the forces in secondary elements are assumed to be smaller than the forces in primary elements. The thermal force is therefore assumed to be a second-order effect that can be neglected in the ultimate limit state. The assumption is correct for the primary frame, whose stiffness is large and whose thermal force is distributed over many members. It is not correct for the bracing member, whose axial stiffness is small, whose force is concentrated in a single component, and whose connection is designed at the limit of its resistance.

5.4.2 The consequence of the classification

The consequence of the classification is not that the force is absent — the force is present regardless of how it is classified. The consequence is that the force is absent from the calculation, and therefore absent from the utilisation ratio and from the design decision. The designer who performs the verification of Section 3 reports ηb, E d=0.944 and concludes that the member is safe. The conclusion is correct within the domain of the brief and incorrect outside it, and the domain of the brief does not contain the force that governs.

The consequence is compounded by the fact that the compatibility force is not a small perturbation. At the upper bound of §5.3.1, the thermal force alone is 39.6% of the design force, and at the upper bound of the restraint it is 145.0 kN, which is 72.6% of the local buckling resistance of the wall at the connection. The force is not a second-order correction; it is a first-order component of the total force, and its omission is not a refinement of the calculation but a change in the question that the calculation answers.

This is the quantitative expression of argumentative thread 4: the load case that produces the failure is not in the design brief. The failure is produced by the combination of the design force and the compatibility force, and the compatibility force is not in the brief. The conventional verification, performed on the design force alone, answers a question that is well-posed but incomplete: it answers whether the member can carry 366.0 kN, and the member cannot carry 366.0 kN either — its local buckling resistance at the connection is 199.8 kN — but the question it answers is not the question that governs, because the force that governs is not 366.0 kN but 321.6 kN to 511.0 kN, and the member is unsafe throughout that range.

5.4.3 The classification does not remove the force

It must be stated explicitly, because the argument depends on it, that the classification of the compatibility force as an indirect action does not remove the force from the member. The member is a physical object connected at both ends to a frame that restrains its deformation. The force that develops is a consequence of the restraint, not of the classification. The classification determines whether the force is calculated, not whether it is present. A force that is present but not calculated is a force that is not designed for, and a member that is not designed for a force that is present is a member whose resistance is not verified against the force that governs.

The remedy is not to reclassify the force — the classification is correct within the framework of SR EN 1990 — but to recognise that the ultimate limit state verification of a slender compression member with a thin-walled connection must include the compatibility force, because the resistance of the connection is of the same order as the compatibility force. When the resistance of the governing component is 199.8 kN and the compatibility force is 145.0 kN, the compatibility force is not a second-order effect; it is 72.6% of the resistance. The threshold at which an indirect action becomes a first-order effect is the ratio of the force to the resistance of the governing component, and for this configuration that ratio is not small.

5.4.4 Summary of Section 5

The load case that is missing from the design brief is the combination of the design force with the compatibility forces arising from thermal variation, foundation settlement, creep, loss of preload, and construction tolerances. These forces are real, unavoidable, and uncontrolled by any element of the connection. Their dispersion is large: the total force ranges from 321.6 kN to 511.0 kN for the thermal force alone, and the upper bound exceeds the design force by 39.6%. At the upper bound, the conventional verification fails (ηb, max=1.32), and the mechanical verification fails throughout the range (ηlocal∈[1.61, 2.56]). The classification of the case as an indirect action is formally correct but has the consequence that the governing force is absent from the calculation. The absence is not a refinement of the calculation; it is the omission of the force that governs, and it is the quantitative expression of the argument that the load case producing the failure is not the load case of the design brief.

6. Plastic distribution and failure mode

6.1 Ductile/brittle contrast between the two failure modes

The two verifications of Sections 3 and 4 do not only produce different utilisation ratios; they predict different modes of failure, and the modes differ not in degree but in kind. The difference is decisive for the design, because a mode of failure that is ductile can be detected before collapse and can redistribute stress, whereas a mode of failure that is brittle cannot.

6.1.1 The mode of failure of the conventional verification

The conventional verification of Section 3 predicts a failure mode that is ductile in both of its components.

The first component is the local buckling of the compressed wall under uniform compression, represented by the effective width of §3.1.2. When a plate element buckles locally, the out-of-plane deflection grows with the load, and the post-buckling path exhibits a stable plateau: the effective width decreases as the load increases, but the plate continues to carry the load over the remaining effective width, and the collapse occurs only when the effective width reaches the value at which the effective stress attains the yield strength. The deformation at collapse is not concentrated — it is distributed over the length of the buckled zone, and it is preceded by a visible out-of-plane deflection that can be detected by inspection. The failure is ductile in the sense that the plate yields progressively before it fails, and the strain at the collapse of the effective section is of the order of the yield strain, fy/E=275.0/210000.0=1.31×10−3, which is well within the ductility of the steel.

The second component is the flexural buckling of the member, represented by the reduction factor χ of §3.1.5. Flexural buckling is also a ductile mode for a member with a relative slenderness of λ̄=0.434, which is below the threshold λ̄=1.0 at which the post-buckling path becomes unstable. At λ̄=0.434, the member reaches its ultimate load after the section has yielded over a portion of its length, and the failure is preceded by a visible lateral deflection and by a measurable increase of the strain at mid-height. The deformation at collapse is of the order of L/200 to L/100, which for L=3000.0 mm is 15.0 to 30.0 mm — detectable by inspection and measurable by instrumentation.

The conventional failure mode is therefore ductile in both of its components: it is preceded by visible deformation, it exhibits a stable post-peak path, and it allows the redistribution of stress from the buckled region to the adjacent regions before the collapse of the section.

6.1.2 The mode of failure of the mechanical verification

The mechanical verification of Section 4 predicts a failure mode that is brittle, not because the steel is brittle — the steel is the same S275 steel — but because the geometry of the connection and the distribution of stress concentrate the demand into a region of small volume whose failure is not preceded by a redistribution of stress.

The wall at the connection is subjected to a peak longitudinal stress of σx=425.9 MPa, a transverse stress of σy=127.8 MPa, a shear stress of τxy=85.2 MPa, and a von Mises equivalent stress of σvm=406.3 MPa, as calculated in §4.2 and §4.3. The volume of material over which this stress state is present is small: it is the region of the wall adjacent to the weld, of length lw=300.0 mm and of width of the order of the wall thickness, t=3.0 mm, so that its volume is of the order of 300.0×3.0×3.0=2700.0 mm3 per wall. Outside this region, the stress decays rapidly to the average value of 319.4 MPa and then to the edge value of 212.9 MPa.

The consequence of the concentration of demand into a small volume is the following.

The yield does not spread. In a ductile mode, the yield spreads from the highly stressed region to the adjacent less-stressed regions, and the section as a whole attains its plastic capacity. In the concentrated mode, the yield is confined to the weld-adjacent region because the adjacent material is stressed at a level below yield and cannot accept the redistributed demand without itself yielding. The concentration is therefore maintained rather than relieved by the yielding of the peak region.

The fracture initiates at the weld toe. The von Mises stress of 406.3 MPa is 94.5% of the ultimate strength fu=430.0 MPa. At the weld toe, the stress concentration factor of the fillet weld, for a throat of a=2.1 mm and a leg of z=3.0 mm, is of the order of Kt=2.0 to 3.0 under axial loading. The local stress at the toe is therefore

σtoe=Ktσvm=2.5×406.3=1015.8 MPa

which is far above the ultimate strength of the steel and of the same order as the strength of the weld metal. The local stress at the toe is not a nominal stress — it is a linear-elastic concentration that is limited in reality by local yielding, but the local yielding at the toe is the mechanism of crack initiation, not of redistribution. The first cycle at the design force produces local plastic strain at the toe that is not recovered, and the accumulation of that strain over repeated cycles produces a fatigue crack.

The failure is not preceded by global deformation. The global deformation of the member at the design force is small: the axial shortening is NE dL/(E A)=366000×3000.0/(210000.0×2348.6)=2.2 mm, and the flexural deflection under a concentric load is zero. The deformation that precedes the failure is concentrated at the weld toe, where it is of the order of the plastic strain at the crack tip, εtip∼10−2 to 10−1, over a length of the order of the wall thickness. This deformation is not visible by inspection and is not measurable by conventional instrumentation. The failure is therefore brittle in the structural sense: it occurs without prior global deformation, without redistribution, and without the warning that the ductile mode provides.

6.1.3 The contrast stated quantitatively

The contrast between the two modes is summarised by the following table, which compares the quantities that govern each mode:

QuantityConventional mode (§3)Mechanical mode (§4)
Governing componentMember, away from connectionWall at connection
Governing stress (MPa)228.4 (uniform)406.3 (von Mises peak)
Stress / yield strength0.8311.48
Stress / ultimate strength0.5310.945
Volume of material at peak demandFull effective area∼2700.0 mm3 per wall
Stress concentration at weld toeNot applicableKt≈2.5
Prior global deformation at failure15.0 to 30.0 mm<0.1 mm
Redistribution before failureYes (effective width)No (Class 4, no plastic redistribution)
ModeDuctileBrittle (crack initiation at toe)

The two modes are not two estimates of the same quantity. They are two different physical processes, with different governing stresses, different volumes of material at peak demand, and different warnings before failure. The conventional mode is ductile because the demand is distributed over the full effective area and the post-buckling path is stable. The mechanical mode is brittle because the demand is concentrated into a small volume whose yielding does not relieve the peak and whose local stress exceeds the ultimate strength.

6.2 Limits of plastic redistribution

The conventional verification of Section 3 permits, within its own logic, a redistribution of stress from the buckled region to the adjacent regions, because the effective width model of SR EN 1993-1-5 is a post-buckling model: it represents the plate as carrying the load over the effective width after the central region has buckled, and it therefore embodies a redistribution from the buckled zone to the supported edges.

This redistribution is not permitted, however, for the wall at the connection, and the reason is the cross-section class. The cross-section is Class 4 (§2.4), and for Class 4 sections SR EN 1993-1-1 and SR EN 1993-1-5 require an elastic verification: the stress distribution is linear-elastic, the effective width is calculated for the elastic buckling of the plate, and no plastic redistribution of stress is permitted. The redistribution that the effective width model embodies is a redistribution within the elastic regime — from the buckled region to the elastic edges — not a redistribution in the plastic regime from a yielded region to an elastic region.

The consequence is that the wall at the connection has zero plastic redistribution capacity. The peak stress of 425.9 MPa at the centre line cannot be redistributed to the edges of the wall, because the edges are stressed at 212.9 MPa and the redistribution would require them to yield — which is precisely what Class 4 does not permit. The peak stress is therefore maintained until the material at the peak fails, and the failure occurs at the peak, not at the section.

This is the quantitative expression of the fact that the resistance of the wall at the connection is governed by the mechanism, not by the section. A Class 1 or Class 2 section would have permitted a plastic redistribution from the peak to the adjacent regions, and the failure would have been governed by the plastic capacity of the section, which is a section property. A Class 4 section does not permit this redistribution, and the failure is governed by the local buckling of the wall at the connection, which is a mechanism property. The distinction is not a matter of the numerical value of the resistance; it is a matter of the physical quantity that governs the resistance.

6.2.1 The case of the bolt

The same limit applies to the bolted connection. The bolts are M20 class 10.9, with a preload of Fp, c=171.5 kN per bolt and a slip resistance of Fs, R d=82.3 kN per bolt (§2.6). The design force per bolt is NE d/2=183.0 kN, which exceeds the slip resistance by 2.22 times. The connection therefore operates in bearing, and the bearing stress at the hole is

σbearing=NEd/2dt=18300020.0×3.0=3050.0 MPa

which exceeds the bearing strength fb=490.0 MPa by a factor of 6.22. The bearing resistance of §2.6, Fb, R d=86.0 kN per bolt, is based on a plastic distribution of the bearing stress over the hole, which requires the steel around the hole to yield and redistribute. For a wall of 3.0 mm, the plastic zone around the hole is of the order of the hole diameter, and the bearing failure is not preceded by a global redistribution. The bearing failure is therefore local and brittle in the same sense as the local buckling of §6.1.2: it is concentrated around the hole, it does not relieve the peak, and it produces a crack that propagates through the wall.

The bolt and the wall at the connection are therefore both governed by mechanisms whose redistribution capacity is limited by the class of the section and by the thickness of the wall. The plastic capacity of the section, Npl, R d=A fy/γM0=2348.6×275.0=645.9 kN, is not available to either component, because the section is Class 4 and the plastic capacity requires a redistribution that Class 4 does not permit. The plastic capacity of the section is a number that the conventional verification does not use, and the mechanical verification cannot use, because the mechanisms that govern do not permit the redistribution on which it is based.

6.3 Stress concentration and degradation

6.3.1 Fatigue

The stress concentration at the weld toe, quantified in §6.1.2 as Kt≈2.5, produces a local stress range under repeated loading that is large even when the applied force range is moderate. For the force range of Section 2.5, ΔN=120.0 kN, the uniform stress range is

Δσconv=ΔNAeff=1200001602.2=74.9 MPa

but the local stress range at the weld toe is

Δσtoe=KtΔσvm=2.5×406.3366.0×120.0=2.5×133.2=333.0 MPa

The local stress range of 333.0 MPa is 4.45 times the uniform stress range of the conventional verification. For a welded detail in a wall of 3.0 mm, the detail category according to SR EN 1993-1-9 is at most ΔσC=56.0 MPa (detail 7.1, fillet weld in a thin-walled section), and the constant-amplitude fatigue limit is ΔσD=0.737×56.0=41.3 MPa. The endurance at the local stress range is

N=ΔσC3×2×106Δσtoe3=56.03×2×106333.03=3.512×10113.692×107=9510cycles

The endurance of 9510 cycles is reached in a few years of service for a bracing member subjected to 120.0 kN of repeated loading. The conventional verification does not contain a fatigue check because the design brief does not specify a fatigue load case, but the fatigue damage is produced by the local stress range at the weld toe, which is a consequence of the load introduction, not of the applied force. The fatigue failure is therefore a degradation mechanism that is invisible to the conventional verification and that is governed by the same local stress state that governs the static failure of §6.1.2.

6.3.2 Wear

The slip of the bolted connection, quantified in §2.6 as NE d/2=183.0 kN against a slip resistance of Fs, R d=82.3 kN per bolt, produces a relative displacement at the interface of the gusset and of the slotted walls. The slip displacement per cycle is of the order of the hole clearance, 2.0 mm, and the repeated slip produces wear of the faying surfaces. The wear reduces the friction coefficient from the initial value of μ=0.3 to a residual value that, for dry surfaces, can be as low as μres=0.1. The slip resistance therefore decreases from 164.6 kN to 54.9 kN over the design life, and the connection transitions further into bearing mode. The bearing stress at the hole, already 3050.0 MPa in the initial state (§6.2.1), is maintained, and the wear produces a progressive ovalisation of the hole that reduces the bearing area and increases the local stress.

The wear is a degradation mechanism that is invisible to the conventional verification, which assumes a constant slip resistance and a constant friction coefficient. It is governed by the same mechanism — the inadequacy of the connection to transmit the force without slip — that governs the static failure of §4.1 and the fatigue failure of §6.3.1.

6.3.3 The weld throat as a degradation-sensitive detail

The correction established in §2.2 gives the weld throat as a=2.1 mm, limited by the thickness of the wall (z=3.0 mm). This value is below the minimum throat required by SR EN 1993-1-8, Table 4.5, which for a wall of t ≤ 3.0 mm requires amin=3.0 mm. The consequence is twofold.

The weld is not code-compliant. The fillet weld of a=2.1 mm on a wall of 3.0 mm cannot be executed to the minimum throat required by SR EN 1993-1-8 without exceeding the leg size that the wall can accept. The detail is therefore not realisable with a standard fillet weld, and the designer is forced either to accept a non-compliant weld or to change the detail — for example, a partial-penetration butt weld, a flare-bevel groove weld, or a local thickening of the wall at the connection.

The non-compliant weld is a degradation-sensitive detail. A throat of 2.1 mm on a wall of 3.0 mm produces a stress concentration at the toe that is higher than that of a compliant weld, because the ratio a/t=0.7 is at the lower limit of the range in which the weld profile is smooth. The fatigue endurance of §6.3.1, N=9510 cycles, is calculated for a compliant weld; for a non-compliant weld, the endurance is lower, and the scatter is larger. The detail is therefore not only non-compliant — it is also more sensitive to degradation than a compliant detail, and its degradation is invisible to the conventional verification for the same reason as the static failure: the conventional verification does not model the weld.

6.4 Conclusion: the governing component governs through a mechanism, not through a section

The conclusion of Section 6 is stated in the form in which it is carried into Section 7.

The conventional verification of Section 3 identifies the flexural buckling of the member as the governing check, with a resistance of Nb, R d=387.7 kN. The resistance of 387.7 kN is a section-and-member property: it is calculated from the effective area of the section, the yield strength of the material, and the reduction factor of the member. The failure that it predicts is a global failure of the member, preceded by visible deformation and exhibiting a stable post-peak path.

The mechanical verification of Section 4 identifies the local buckling of the wall at the connection as the governing mechanism, with a resistance of Ncr, local, total=199.8 kN. The resistance of 199.8 kN is a mechanism property: it is calculated from the effective width of the loaded region of the wall, the line load transmitted by the weld, and the stress concentration at the weld toe. The failure that it predicts is a local failure of the wall at the connection, not preceded by visible deformation and not exhibiting a stable post-peak path.

The two resistances are not two estimates of the same quantity. They are two answers to two different questions. The conventional verification answers the question "can the isolated cross-section, subjected to a uniform compressive stress, carry the design force without local buckling of its plate elements and without flexural buckling of the bar?", and it answers it correctly, with ηb, E d=0.944. The mechanical verification answers the question "does the connection introduce the force in a manner consistent with the uniform-stress assumption under which the resistance of 387.7 kN was calculated?", and it answers it negatively, with ηlocal, E d=1.83. The second answer is not contained in the first, because the first does not model the connection, and the connection is where the governing mechanism resides.

The consequence for the hierarchy of §4.4.2 is that the governing component is not the one with the smallest cross-section. The weld has the smallest throat (a=2.1 mm) and is not the governing component. The cross-section has the largest area (2348.6 mm2) and is not the governing component. The governing component is the wall at the connection, whose cross-sectional area (573.0 mm2 per wall) is intermediate, and whose resistance is governed by a mechanism — local buckling of the loaded region — that is not a function of the cross-sectional area alone. The governing component governs through the mechanism, not through the section, and the mechanism is at the connection, not in the member.

The failure mode that the mechanism produces is brittle in the structural sense of §6.1.2: it is preceded by no visible global deformation, it exhibits no stable post-peak path, it is not preceded by plastic redistribution (Class 4 does not permit it), and it is initiated at the weld toe where the local stress exceeds the ultimate strength of the steel. The conventional verification, which predicts a ductile mode, does not detect the brittle mode because the brittle mode is not in its domain. The contrast between the two modes is the contrast between two different physical processes, and it is the final quantitative expression of the argument of this article: the conventional verification and the governing mechanism answer different questions, and the answer to the second is not contained in the answer to the first.

7. Conclusion

7.1 Summary of findings

The investigation was carried out on a single, fully defined reference configuration — a cold-formed SHS 200 × 200 × 3.0 of grade S275, of length L=3000.0 mm, compressed through slotted gusset connections welded to two opposite walls — and it compared two verifications of the same member. The conventional verification, executed in Section 3, followed the sequence prescribed by SR EN 1993-1-1 and SR EN 1993-1-5. The mechanical verification, executed in Section 4, modelled the introduction of the force at the connection and the stress state that the introduction produces. The findings are the following.

The cross-section is Class 4, and the verification is elastic. With c/t=63.7 and 42ε=38.8, the compressed wall exceeds the Class 3 limit and the resistance is governed by the effective width. The effective width is beff=128.8 mm against a flat width of c=191.0 mm, and the effective area is Aeff=1602.2 mm² against a gross area of A=2348.6 mm² — a reduction to 68.2% of the gross area. No plastic redistribution is permitted, and this prohibition is decisive for the whole of the subsequent argument.

The conventional verification is satisfied at the design load. The cross-section resistance is Nc, R d=440.6 kN, the flexural buckling resistance is Nb, R d=387.7 kN, and the governing utilisation is ηb, E d=0.944. The arithmetic of Section 3 has been reproduced in full and is correct: the classification, the plate slenderness λ̄=1.214, the reduction factor ρ=0.674, the relative slenderness λ̄=0.434, and the buckling reduction factor χ=0.880 are all correctly obtained.

The mechanical verification is not satisfied, and the margin is large. The force is introduced into each wall at a line load intensity of q=0.610 kN/mm over the weld length lw=300.0 mm. The local buckling resistance of the wall at the connection is Ncr, local=99.9 kN per wall, and Ncr, local, total=199.8 kN for the member. The utilisation is ηlocal, E d=1.83, and the ratio between the conventional and the mechanical resistance is 387.7/199.8=1.94.

The real stress distribution is non-uniform and its peak is close to the ultimate strength. The average longitudinal stress over one wall is σavg=319.4 MPa, which already exceeds the yield strength by 16.1%. The peak at the centre line is σpeak=425.9 MPa, or 1.86 times the uniform stress of 228.4 MPa assumed in the conventional verification. With σy=127.8 MPa, τxy=85.2 MPa, the von Mises equivalent stress is σvm=406.3 MPa, which is 1.48 times the yield strength and 0.945 times the ultimate strength. The conventional verification does not merely underestimate this stress — it computes a different stress in a different stress state.

The weakest component is not the one with the smallest cross-section. The weld has the smallest throat (a=2.1 mm) and the largest capacity (556.2 kN). The cross-section has the largest area and a capacity of 440.6 kN. The governing component is the wall at the connection, of intermediate area, with 199.8 kN. The hierarchy follows the severity of the mechanisms, not the size of the sections: 164.6 kN (bolt slip) < 172.0 kN (bolt bearing) < 196.0 kN (bolt shear) < 199.8 kN (wall local buckling) ≪ 387.7 kN (flexural buckling) < 440.6 kN (cross-section) < 556.2 kN (weld).

The load case that produces the failure is not in the design brief. The compatibility force from a thermal variation of 25.0 K with a 50% restraint is 74.0 kN, giving a total force of 440.0 kN. Over the realistic ranges of temperature (−25.0 to +35.0 K) and restraint (30% to 70%), the total force ranges from 321.6 kN to 511.0 kN. At the upper bound the conventional verification fails with ηb, max=1.32; the mechanical verification fails throughout the range, with ηlocal∈[1.61, 2.56]. The compatibility force is not calculated because it is classified as an indirect action, and the classification determines whether the force is calculated, not whether it is present.

The failure mode is brittle in the structural sense. The conventional mode is ductile: it is preceded by 15.0 to 30.0 mm of global deformation and exhibits a stable post-peak path. The mechanical mode is local: the stress concentration at the weld toe is Kt≈2.5, giving a local stress of 1015.8 MPa, the volume at peak demand is of the order of 2700.0 mm³ per wall, and the prior global deformation is below 0.1 mm. The local stress range under ΔN=120.0 kN is Δσtoe=333.0 MPa against a detail category of 56.0 MPa, giving an endurance of 9510 cycles. The detail is additionally non-compliant, since a=2.1 mm is below the amin=3.0 mm required by SR EN 1993-1-8, Table 4.5.

7.2 Engineering takeaways

The conventional verification is correct in itself; the deficiency is of scope. No arithmetic error was found in Section 3. The classification, the effective width, the effective area, the buckling curve, and the partial factors are all correctly applied. The verification answers a well-posed question correctly. It fails to answer the governing question not because it computes badly, but because the connection is outside its domain.

The governing mechanism is not represented by the conventional verification. The resistance of 199.8 kN at the connection and the resistance of 387.7 kN of the member differ by a factor of 1.94, and the difference is not a coefficient that could be introduced into the conventional formula. It is the consequence of a different physical model, with a different load introduction and a different boundary condition.

The real stress distribution is non-uniform and invisible to the global verification. The peak stress of 425.9 MPa and the equivalent stress of 406.3 MPa are not obtainable from the global quantities NE d and Aeff. They require the line load q, the spread width be, and the stress concentration at the toe — quantities that belong to the connection, not to the member.

The load case that produces the failure is not in the design brief. The total force ranges from 321.6 kN to 511.0 kN, and the range is produced by phenomena that are classified as indirect actions. The classification is formally correct and practically unsafe, because the resistance of the governing component (199.8 kN) is of the same order as the compatibility force (145.0 kN).

The weakest component is not the one with the smallest cross-section. The ranking of capacities follows the ranking of mechanisms. The weld is the strongest component and the wall at the connection is the governing one, although neither is the smallest nor the largest section.

The resistance of the assembly is the resistance of the component with the most severe mechanism. The assembly resists 164.6 kN governed by bolt slip, or 199.8 kN if the bolted interface is treated separately, governed by local buckling of the wall. In neither case is the resistance of the assembly governed by the flexural buckling of the member, which is the mechanism identified by the conventional verification.

7.3 Recommendations for design

Include the compatibility force in the ultimate limit state verification of slender bracing members. When the resistance of the governing component is of the same order as the compatibility force, the force cannot be treated as a second-order effect. A quantitative threshold is recommended: the compatibility force should be included whenever it exceeds 10% of the resistance of the governing component. For the configuration examined, that ratio is 72.6%, and the omission is not a refinement but an error of scope.

Verify the connection against the local stress state, not only against the member force. The check should be performed with the line load q=Nw/lw, the spread width be, the local plate slenderness λ̄p, local, and the stress concentration at the weld toe. A connection that satisfies the member verification may still be utilised at 183% of its local resistance.

Classify the cross-section and carry the classification into the connection design. For Class 4 sections, no plastic redistribution is available, and the peak stress at the connection cannot be shed to the adjacent material. The connection of a Class 4 member must therefore be designed for the elastic peak, not for an average or a plastic value.

Do not assume that the component with the smallest section governs. Identify the governing mechanism for each component and rank the components by the severity of the mechanism. The capacity ranking should be established explicitly, as in §4.4.2, before the design is closed.

Ensure that the connection detail is realisable within the thickness of the connected parts. For a wall of 3.0 mm, a fillet weld cannot achieve the minimum throat of amin=3.0 mm required by SR EN 1993-1-8, Table 4.5, and the detail must be changed — to a partial-penetration butt weld, a flare-bevel groove weld, or a local thickening of the wall at the connection. A detail that cannot be executed to the code cannot be verified to the code.

Design the connection for slip-resistant behaviour where repeated loading is present, or verify the bearing and fatigue explicitly. The transition from slip-resistant to bearing mode changes the load path, increases the local stress, and produces wear that reduces the friction coefficient. Where the slip resistance is exceeded, the bearing and fatigue verifications must be performed explicitly, and the endurance at the weld toe must be compared with the design life.

Provide a reserve consistent with the dispersion of the compatibility force. The upper bound of the total force exceeds the design force by 39.6%, and the conventional utilisation at the upper bound is ηb, max=1.32. A reserve that is adequate for the design force is not adequate for the total force, and the design should be closed at the upper bound of the total force rather than at the design force.

Report both verifications, and state which question each answers. The utilisation ratio ηb, E d=0.944 and the utilisation ratio ηlocal, E d=1.83 are not two estimates of the same quantity. They should be reported as answers to two different questions, so that the design decision is taken on the governing question and not on the question that happens to have been calculated.

7.4 Concluding remarks

The article set out to demonstrate, quantitatively and not by assertion, that the conventional verification and the governing mechanism answer different questions, and that the answer to the second is not contained in the answer to the first. The demonstration has been carried through on a single configuration, with all intermediate quantities reproduced so that each step can be verified independently.

The result is stated in three sentences. The conventional verification of Section 3 is correct: it reports ηb, E d=0.944 for the isolated cross-section under a uniform compressive stress, and the arithmetic is sound. The governing mechanism of Section 4 is local buckling of the wall at the connection, and it reports ηlocal, E d=1.83 for the member as it is actually loaded. The two answers differ by a factor of 1.94 in resistance, by a factor of 1.86 in peak stress, and by a difference of kind — not of degree — in the mode of failure, which is ductile in the first case and brittle in the structural sense in the second.

The deficiency is therefore not arithmetic but of scope. The conventional verification substitutes a uniform stress distribution for the real one, a concentric load for the real one, and an isolated bar for the real member-with-connection. Each substitution is legitimate within the domain of the verification; none of them is legitimate outside it, and the connection is outside it. The question that governs the design is whether the connection introduces the force in a manner consistent with the assumptions under which the resistance was calculated. That question is not answered by the conventional verification, and it cannot be answered by it, because the connection is not in its domain.

The practical consequence is stated without qualification. The member examined in this article satisfies the conventional verification and does not satisfy the mechanical verification; the difference is not a margin of a few percent but a factor of nearly two in resistance and a mode of failure that is not represented in the calculation. The load case that produces the failure is not in the design brief. The component that governs is not the one with the smallest section. The resistance of the assembly is the resistance of the component with the most severe mechanism, and the most severe mechanism is at the connection.

The article does not argue that the conventional verification should be abandoned. It argues that the conventional verification should be performed, reported for what it is, and supplemented by the verification of the connection, because the two answer different questions and only the second governs the design. The cross-section class decides whether a plastic or an elastic verification applies; the effective width governs the resistance of the slender compression element; and the connection decides whether the member behaves as verified. All three statements are operative in the configuration examined, and the third is the one that governs.

Technical Notes

The notes below accompany the article and do not form part of its argumentative body. They define the purpose and the limits of the investigation, state a necessary distinction between local failure and global failure, and issue an invitation to professional debate.

Technical Note 1 — Purpose of the article and the place of detailed analysis

The article does not advocate a change in the way compressed elements or thin-walled sections are calculated. The methods of SR EN 1993-1-1 and SR EN 1993-1-5 — the classification of the cross-section, the effective width, the buckling curves — are correct within their domain of validity, and their rigorous application remains mandatory. What the article maintains is that there is room for a detailed analysis where the global verification does not cover the governing mechanism, and that this detailed analysis does not replace the code but completes it in the areas that the code does not model — in particular at the introduction of the force into the section, that is, at the connection.

A practical consequence of this position is that good design is, in normal circumstances, the result of collaboration between engineers of different disciplines and competences: the structural engineer who masters the code and the classification, the connection engineer who masters the detail and the fabrication technology, the fabrication engineer who knows the real tolerances and the behaviour of a weld on a thin wall, and, where appropriate, the mechanical engineer who knows the real regime of loading and degradation of the assembly. Each of them sees a different part of the same problem, and failure occurs, as a rule, in the zone where none of them was invited to look. The detailed analysis of Section 4 is not an exercise in academic virtuosity; it is the quantitative argument for the necessity of that collaboration.

Technical Note 2 — Local failure and global failure

A local failure does not necessarily produce a global failure. A wall that buckles locally at the connection, a weld that cracks at the toe, a bolt that slips in bearing mode — none of these implies, by itself, the collapse of the assembly. The structure may remain standing, and may even continue to carry the load through partial redistributions; in certain situations the local degradation is acceptable and is accepted explicitly by the designer.

For that very reason, the engineer must judge whether the design corresponds to the purpose and to the real mode of operation of the elements. The question is not whether local failure is possible — it almost always is — but whether it is compatible with:

the functional purpose of the element (a bracing member that deforms locally may compromise its function of limiting displacements, even if it does not collapse);

the real regime of loading (static, cyclic, with thermal compatibility, with settlement, with loss of preload);

the design life (a local degradation that does not endanger immediate safety may reduce durability below the design life);

the requirements of inspectability and maintenance (a local degradation that is invisible at inspection cannot be managed).

The distinction between "it does not collapse" and "it corresponds to the purpose" is essential. The article demonstrates quantitatively that local failure at the connection is possible and probable; it does not demonstrate, and does not intend to demonstrate, that it produces global collapse. What it demonstrates is that local failure is not represented in the global verification, and that the decision to accept it or to eliminate it must be taken with full knowledge of the facts, not by omission.

Technical Note 3 — Invitation to debate

Articles of this kind — which subject a detail commonly regarded as settled to a quantitative analysis, which compare two verifications that answer different questions, which question the boundary between "verified" and "designed" — are useful only if they are read critically, contested, and corrected. A thesis that is not subjected to professional antagonism remains an opinion; a thesis that is subjected to antagonism and survives becomes knowledge.

Engineers are encouraged to discuss and contest the article: to verify the arithmetic of Sections 3 and 4, to contest the assumptions of §4.1.1 (the spread width be, the buckling coefficient kσ, the linear stress distribution), to propose alternative models for the introduction of the force, to contest the hierarchy of §4.4.2, to bring experimental data or finite-element results that confirm or refute the local resistance of 199.8 kN, to contest the treatment of the compatibility force in Section 5, to propose different criteria for its inclusion in the design brief. Each of these contestations is welcome, and those that prove to be well founded must lead to the correction of the article.

Debate on calculations and on technical codes is not a lack of respect for the code; it is the mechanism by which the code is improved and by which the understanding of the phenomena is deepened. Codes are written by committees that synthesise the knowledge available at a given moment, and the available knowledge is produced in large part through debates of this kind — on concrete cases, with verifiable calculations, with explicit assumptions, and with conclusions that can be contested. From this comes progress, and from this comes understanding.